Dysan DC14 Duct Replacement

The new duct will not come with any additional...

iFixit Library Dyson DC14 Difficult 3 hours Guide 102524
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

The new duct will not come with any additional attached pieces. The old duct will need to be picked clean of parts and transferred to the new one, including rubber gaskets. You will need a Torx T15 driver. A T15 bit with separate driver will not work, as the shanks on these are too large to fit into some of the deep well holes. The driver will need to be about 4” long. Your machine may require the security version - being hollow, or having a hole in the end to mate with a pin found in anti-tamper T15 fasteners. Throughout this process, it is important to keep in mind that it is more important to not damage pieces that you are removing than it is to not damage the part you are replacing. If you are tempted to force something, make sure what may get broken is the part you are planning on throwing away anyway, rather than the part you are attempting to salvage from it. If you think you might get confused, there is no shame in taking pictures. Lots of pictures. For clarification of terms like cyclone assembly, u-bend pipe, intake cover, exhaust cover, hose assembly, exhaust seal, entry seal, pre-filter seal, cleaner head, port plate, exhaust pipe assembly, etc., refer to online replacement parts diagrams.

Step 1

Make Sure the Unit is Unplugged.

  • Avoid frightening the house cats.
Step 2

Remove All Snap-In Pieces

  • Remove dust receptacle (Cyclone Assembly) and any attachments and set aside.
  • Remove the u-bend pipe, intake cover, exhaust cover and set aside.
Step 3

Remove the Hose Assembly

  • Remove the hose assembly by releasing it from the bottom by depressing a latch via a hole through the lower half of the duct while pulling it upward.
Step 4

Remove the Switch Cover Plate

  • Remove the screw(s) from the power switch cover plate, found on the opposite site of the duct from the power switch. The cover plate swings away from the duct at the top, then lifts up and off. Set it and the power button aside.
Step 5

Remove the Power Cord

  • Pull the motor power cord out of the channel.
  • Disconnect the white wire at the connector below the power switch.
  • Pull the power switch and the wall cord that should still be attached by its black wire out of the old duct.
Step 6

Transfer the Power Cord and Switch

  • Install the power cord and switch into the new duct.
Step 7

Remove the Motor Wires

  • Pull both the black and white motor wires out of the opening they go through at the top of the duct. Note the location of this opening.
  • Pull the motor wires out of the channel they are embedded into all the way to the bottom.
Step 8

Transfer the Exhaust Seal

  • Remove the oval black rubber gasket (exhaust seal) at the top of the duct and install it on the new duct. Notice that there is a notch in the gasket that must be aligned for proper installation.
Step 9

Transfer the Entry Seal

  • Slightly below the exhaust seal is another rectangular rubber gasket (entry seal). Transfer it to the new duct, noting it too has a notch that needs to be aligned properly.
Step 10

Exhaust Pre-Filter Seal

  • You do not need to transfer the bottom most seal (exhaust pre-filter seal) over to the new duct. The part that it is installed on will be transferred to the new duct and will move with it. This step is coming up soon
Step 11

Crevice Tool Clip

  • Remove the crevice tool clip and install it onto the new duct.
Step 12

Canister Latch

  • Squeeze the sides of the canister latch and pull it out. Do not lose the spring behind it. Reinstall the latch and spring onto the new duct.
Step 13

Remove ONLY ONE Wheel

  • Pry off the hubcap.
  • Remove the metal e-clip from the shaft. This clip will attempt to fly across the room and vanish from this dimension. Do not let it.
  • Pull the small metal washer and the wheel from the shaft.
Step 14

Transfer the Wheels

  • Slide the remaining wheel and shaft out and reinstall it and the other wheel back onto the new duct.
Step 15

Cleaner Head Assembly

  • The pivot points for the Cleaner Head assembly have two plastic Bearing Clips, the ends of which are embedded into a recess on their shafts. Pry the ends out the recess and work the clips off of the shafts.
  • Remove the large plastic washers (Cleaner Head Pivot Circlips) underneath the clips.
Step 16

Remove the Motor Inlet Cover Catch

  • Pull out the Motor Inlet Cover Catch. It pulls straight out and may put up a fight.
Step 17

Flip It

  • Turn the unit over.
Step 18

Remove the Sole Plate

  • Remove the sole plate by rotating the three large slotted screws a quarter turn and lifting the plate off, pivoting toward the front.
Step 19

Disconnect the Flexible Hose

  • Yank the flexible hose off of the Port Plate.
Step 20

Remove the Exhaust Pipe Assembly

  • Remove the right rear screw holding the exhaust pipe assembly.
  • Remove the exhaust pipe assembly. This is tricky. It kinda pulls up and to the right
Step 21

Remove the Port Plate

  • Remove the port plate. One end unsnaps then pivots out on the other end. Remember that you are disposing of the piece this is coming out of while trying to save this piece, so act accordingly.
Step 22

Remove the Forward Lock

  • Remove the forward lock and spring by depressing the sides inward to disengage the pivots and then pulling out.
Step 23

Remove the Valve Carriage

  • Remove the valve carriage.
Step 24

Transfer the Valve Carriage to the New Duct

  • Reinstall the valve carriage onto the new duct.
Step 25

Reinstall the Port Plate

  • Reinstall the port plate, by pivoting the widest end first, then snapping the smaller end into place.
Step 26

Transfer the Forward Lock to the New Duct

  • Reinstall the forward lock and spring into the new duct.
Step 27

Transfer the Valve Carriage to the New Duct

  • Reinstall the valve carriage onto the new duct.
Step 28

Remove the old Duct

  • Remove the five remaining screws from the bottom of the unit.
  • Lift the Cleaner Head assembly pivot points over the tops of the shafts.
  • The old duct should now be able to come off and be disposed of. Make sure nothing removable remains on it before disposing.
Step 29

Install the New Duct

  • After removing the old duct from the motor, fit the new one to it.
  • Replace the five screws removed earlier.
Step 30

Reinstall the Exhaust Pipe Assembly

  • Reinstall the exhaust pipe assembly and screw it down.
Step 31

Reinstall the Motor Inlet Cover Catch

  • Reinstall the Motor Inlet Cover Catch. Press it firmly in until it is seated.
Step 32

Reinstall the Cleaner Head

  • Slide the Cleaner Head pivot points back over their pivots.
  • Reinstall the plastic washers (Cleaner Head Pivot Circlips) over the pivots.
  • Reinstall the Bearing Clips onto the pivots and seat the ends back into the recesses for them.
  • Reinstall the Hose Assembly into the base of the duct.
  • Reconnect the flexible hose for the beater bar to the port plate.
  • Reinstall the sole plate that was removed in step 18.
Step 33

Reinstall the Power Cord

  • Starting at the bottom and working upward, press the motor power cord into its channel or groove in the new duct.
  • At the top, pass the motor power cord connectors through the same hole you noted earlier, next to the switch.
  • Reconnect the white wire from the motor to the white wire from the power cord.
  • Reconnect the black wire from the motor to the terminal on the switch.
Step 34

Reinstall the Switch

  • Push the switch back into its slot with the plunger facing up.
  • Reconnect the black wire from the motor to the terminal on the switch.
  • Place the button on top of the switch
Step 35

Reinstall the Switch Cover Plate

  • Reinstall the switch cover plate by first engaging its tabs at the bottom into the new duct, then pivoting it into place. Replace the screw(s) that go in from other side of the new duct.
Step 36

Reinstall All Snap-In Pieces

  • Reinstall the u-bend pipe, intake cover, and exhaust cover.
  • Reinstall the dust receptacle (Cyclone Assembly).