Before you begin

The power switch allows the Hoover Power Path Pro Advanced to turn on with the press of the power button. A defective power switch will not allow the user to control the on and off state of the device and needs to be replaced.

Step 1

Repair step

  • Remove the lower brushroll from the bottom of the cleaner.
Step 2

Repair step

  • Use a long #2 Philips head to remove the 8 numbered screws on the bottom of the cleaner (They will also be indicated on the bottom of the vacuum).
Step 3

Repair step

  • Pull the red handle to remove the front suction unit from the cleaner.
Step 4

Repair step

  • Unscrew the hose by using a Phillips #2 to detach it from the top cover of the cleaner.
Step 5

Repair step

  • Push down on the handle release button. Lift the edge of top cover connected to this button.
  • Repeat the above step for the "On/Off" button.
  • Pull entire top cover off.
  • Caution: when pulling the handle release button, make sure the top of the cleaner does not fall.
Step 6

Repair step

  • Remove the "On/Off" cap by pulling it upwards with caution.
Step 7

Repair step

  • Use a long #2 Philips head to remove the two screws from the arched grey piece.
Step 8

Repair step

  • Pull out the red power the red power switch.