Apple iSight Webcam Camera Replacement

You will be separating the camera module from...

iFixit Library Apple iSight Webcam Difficult 5 - 15 minutes Guide 106656
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

You will be separating the camera module from the rest of the device. This include removing 3 pin tabs/ribbons from the circuit board. You will have to do this carefully as any damage done to the pins will be hard to repair. The rest is just unscrewing screws.

Step 1

Repair step

  • Remove two 3.55 mm screws that hold the body to the ball and socket joint using the PH000 screwhead.
Step 2

Repair step

  • Insert the tweezers into the crevice of the ball and socket joint, and prop up the tabs to remove the white ring from the body.
Step 3

Repair step

  • Press the Apple logo through to pull apart the body frame from the body of the webcam.
Step 4

Repair step

  • Remove the end cap with the Apple logo by simply pulling it off.
Step 5

Repair step

  • Unscrew the 3 (3.55 mm) screws surrounding the black casing near the camera-lens.
Step 6

Repair step

  • Using tweezers, remove the netting that surrounds the black casing.
Step 7

Repair step

  • Pry open the top of the black casing and pull it off.
  • There is slot on each side just below the power cord connector.
Step 8

Repair step

  • Gently pull out the ribbon cables at the base of the circuit board. The camera module and lens cap are connected to the board via two busses.
  • Make sure that all pins are loose before pulling them out or you could risk bending the pins or breaking the connector.
Step 9

Repair step

  • Remove the three PH000 3.55mm screws that connect the end cap that holds the privacy shutter to the rest of the camera enclosure. Once the screw are removed, you can pull them apart.
Step 10

Repair step

  • Unscrew the three PH000 3.55mm screws from the connecting plate and the camera enclosure. Pull apart when all screws are removed.
Step 11

Repair step

  • Unscrew the three PH000 3.55mm screws securing the Camera module circuit board and lens enclosure.
Step 12

Repair step

  • Pull the pin tab from the base of the circuit board to separate the camera module and the lens enclosure.