FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

How to change Tool for DeepAccess

Attributed iFixit repair guide for Bondkopf DeepAccess.

iFixit Library Bondkopf DeepAccess Easy No estimate Guide 107806
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Step 1

Repair step

  • Prepare Tools and replacement parts.
Step 2

Remove wedge from transducer

  • Grab wegdge with tweezers
  • Loosen the screw. (while holding the wedge)
  • Get rid of the copper screw. To NOT use it more than once
Step 3

Place the new wedge in the transducer.

  • Put the wedge in the tranducer from below.
  • Take care, that the Tool Top is flush with the Transducer surface
  • Correct Placement. Tool is flush with transducer.
  • Incorrect Placement. tool is too high.
Step 4

Fasten the copper screw

  • Fasten the screw lightly
  • Tighten the screw just so the wedge does not slip out of the tranducer.
  • in case of appliying too much torque. Use a new screw and get rid of the old one.
Step 5

Adjust wedge heigth with setting gauge

  • Place gauge below Tool
  • Loosen the screw so the wedge slides onto the gauge Lever.
  • Lift the gauge up until in contact with the transducer horn.
  • Now the Tool-Top should be flush with the Transducer-Horn
  • Tighten the screw with the torque- wrench
  • Use Torque wrench with 18cN limitation
Step 6

Thread wire back in wedge hole

  • Use tweezers to push the wire down the wire hole, until it Ends some cm below the tool wedge.
  • Use scissors to cut the (contaminated) Wire down to a length of about 1cm below wedge end.
Step 7

Thread Wire through Wedge-hole

  • Use tweezers to thread the wire through the hole at the end of the wedge.
  • Afet threading pull the wire some cm through the hole.