Step 1

Repair step

  • Use the Phillips #2 screwdriver to remove the four 6 mm screws by unscrewing counterclockwise.
Step 2

Repair step

  • Pull the front and back cover apart.
  • Be careful not to pull the front cover off completely. It holds the wires.
Step 3

Repair step

  • Remove the Phillips 6 mm screw that holds the circuit board to the outer shell of the fan.
  • Shock warning: Make sure the fan is unplugged before removing the circuit board.
Step 4

Repair step

  • Remove the top cover containing the circuit board and the wires by pulling it away from the outer shell of the fan.
Step 5

Repair step

  • Remove the screws from the four corners of the circuit board.
  • Remove the circuit board from the top cover.
  • Do not touch the other side of the circuit board to avoid damaging the circuit elements.
Step 6

Repair step

  • In order to remove the fan blade, use pliers to remove the holding nut.
  • After the holding nut is loose, use the pliers to pull up to remove the nut.
Step 7

Repair step

  • Remove the two bronze Phillips 29-mm bolts that hold the fan blade to the transformer.
  • Use a pair of pliers to hold the nut at the bottom of the transformer, as you unscrew from left-to-right at the top of the transformer. After, pull up and remove both the screw and nut.
Step 8

Repair step

  • Next, remove the two silver Phillips (8-mm head) 40-mm screws from the transformer.
  • Remove screws by pulling them away from the base.
  • The transformer should be free after this step.
Step 9

Repair step

  • Clean the track, removing any obstructions.
  • Lubricate the track with grease.