Before you begin

This repair guide is intended to prevent rattling noise from the sensor in a Logitech G303 computer mouse. There are two different adhesive methods that are described on Steps 6 and 7.

Step 1

Repair step

  • Pry off the mouse feet located at the front and back of the underside of the mouse by wedging a flat head screw driver into the depressed groove and applying upward force.
  • Ensure that the mouse is not plugged into any power source before starting the repair.
  • Carefully remove the feet and be wary of the adhesive. Careful handling will allow them to be reattached and not require the purchase of a new set of mouse feet
Step 2

Repair step

  • Using a Phillips #00 screwdriver, unscrew the three screws that hold the top and bottom halves of the mouse together.
Step 3

Repair step

  • Grip the mouse cable with one had and the top buttons with the other and apply force in opposite directions to separate the two halves of the mouse.
  • Try lightly squeezing the top buttons together while separating the two halves of the mouse.
Step 4

Repair step

  • Using the Phillips #00 screwdriver, unscrew the three internal screws.
Step 5

Repair step

  • Remove the internal operating board by lifting it out of the bottom half of the mouse.
  • Handle the internals carefully to prevent damage from occurring.
Step 6

Repair step

  • First Adhesive Method:
  • Apply a thin bead of the Silicon caulk to the rim of the sensor component.
  • Ensure that no Silicon is covering the center where the sensor is located.
  • The Silicon takes 30 minutes to set. This allows slight adjustments to be made if the Silicon initially covers the sensor.
Step 7

Repair step

  • Second Adhesive Method:
  • Attach the double sided tape to the bottom half of the housing. Place them directly over the central grooves.
  • Ensure that the central hole is not covered so the sensor still functions as designed.