FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Philips steam ironing station GC9640 solenoid valve coil replacement

If the steam ironing station makes heating...

iFixit Library Philips Dampfbügelstation GC9640 Moderate 2 hours Guide 113255
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

If the steam ironing station makes heating noises (boiling water) but does not produce any steam, it may be due to a faulty solenoid valve coil. The price of the valve was 40 € in September 2018 plus shipping. Unfortunately I could not receive the coil individually. Another cause may be a defect in the steam button in the iron handle. These instructions only describe the replacement of the solenoid valve coil.

Step 1

Preparation

  • Pull out the plug. If necessary, allow the device to cool down for 10 minutes. Remove the water tank. Place the iron on a suitable surface.
Step 2

Empty the steam boiler

  • Place a suitable container to catch the water.
  • Unscrew the stopper plug counterclockwise and set it aside.
Step 3

Remove the bottom of the device

  • Turn the device upside down.
  • Use a long screwdriver to remove 6 Torx # 15 screws
  • Remove 2 screws with a Philips # 1 screwdriver
Step 4

Open device

  • Place the unit with the bottom facing downwards. Carefully lift the upper part.
  • The keyboard in the upper part is connected by a cable harness to the motherboard. Grab the corresponding plug on both sides and remove them carefully.
  • Remove the clear hose between the water tank and the pump on the pump side. To do this, grasp under the lower edge of the hose and pull up with bending or rotating movements.
  • The upper part can now be put aside.
Step 5

Measuring the solenoid valve coils resistance

  • Remove the rubber protection cap from the cable lug of the conductor.
  • Disconnect both cables from the spool. To do this, use a pointed object (eg a small screwdriver) to push the lock of the cable lug outwards, and at the same time pulling the cable lug away from the valve.
  • Use a multimeter to measure the resistance between the two contacts. It should (at least briefly) be at 30 ohms. If the resistance is infinite, the coil is defective and needs to be replaced.
  • I could not get the coil individually. The complete valve was available here: https://shop.euras.com/detailsseite_ma.p... In the comments Maxim is showing a reasonable priced source.
Step 6

Removing the solenoid coil

  • In order to disassemble the coil the valve must be turned approximately 30° counterclockwise. Replacing the whole valve doesn't make a lot of sense here, because the pressure hoses are partly glued together or are fixed in place with clamping rings.
  • Remove 2 Phillips screws #1 to give the hose connected to the iron more play.
  • Pull off the cable lug of the heat sensor, while pushing the pawl outwards.
  • Grab the whole valve and turn it counterclockwise until the coil is able to squeeze past the black pressure hose. You may need pliers.
  • Open the fixing nut turning a wrench counterclockwise and pull off the coil.
  • Auf Bild 4-6 kann man den Schlauch sehen, der in den Kommentaren ab 23.5.23 besprochen wird.
Step 7

Repair step

  • It happens that the hose behind the solenoid valve has come loose because the plastic connector has broken.
  • The connecting piece can be replaced by a suitable aluminum tube.
Step 8

Assembly

  • Assembly is done by following the steps in reverse order.