Harman Kardon Invoke Service Port Replacement

If your Invoke is not connecting to your...

iFixit Library Harman Kardon Invoke Easy 10 minutes Guide 115169
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

If your Invoke is not connecting to your computer in order to be serviced, there might be a problem with the service port and should be replaced. For this replacement you will need a metal spudger and a #10 Torx screwdriver.

Step 1

Remove the rubber base

  • Use a metal spudger to remove the rubber bottom.
Step 2

Remove the base screws

  • Use a #10 Torx screwdriver to remove four 14 mm screws.
Step 3

Remove the base

  • Firmly grip the bottom and wiggle upwards to remove the base.
Step 4

Removing the board

  • Use a #10 Torx screwdriver to remove two 10 mm screws from board attached to ports.
  • Pull board up lightly.
Step 5

Disconnect the board

  • Pull cable to disconnect board from device.