Step 1

Repair step

  • Remove the ten 19mm T20 Torx screws shown in red.
Step 2

Repair step

  • Remove the red Housing Assembly by lifting it up off of the tool.
Step 3

Repair step

  • Now the two 10mm T-10 screws shown in red can be removed.
  • Next, remove the two 10mm T-10 screws located on the other side of the tool shown in orange.
Step 4

Repair step

  • Using the metal spudger, remove each brush holder as shown in the images.
Step 5

Repair step

  • Remove the four 37mm T-20 screws shown in red. These screws attach the gear housing to the motor housing.
Step 6

Repair step

  • After removing the four screws, pull apart the the two sections.
Step 7

Repair step

  • Remove the four 12mm screws with a T-15 Torx screwdriver shown in red.
  • These screws hold the fan baffle in place.
Step 8

Repair step

  • Remove the fan baffle by pulling it out.
Step 9

Repair step

  • Pull the black wire(shown in the image) out of the trigger assembly.
Step 10

Repair step

  • Pull the white wire (shown in the image) out of the trigger assembly.
Step 11

Repair step

  • Using a metal spudger slide the black wire (shown in the image) out of the trigger assembly.
Step 12

Repair step

  • Using a metal spudger slide the yellow wire (shown in the image) out of the trigger assembly.
Step 13

Repair step

  • After disconnecting the wires, push the 120v Field Assembly out of the motor housing.
  • You may need to use a screwdriver to push the assembly from behind.
Step 14

Repair step

  • Once the assembly is loose, pull each half out of the housing.
  • Note the orientation of how the halves sit together in the housing before removal.
Step 15

Repair step

  • Remove the motor housing from the device.