Panasonic Lumix DMC-TZ10 Image Sensor Repair

I decided to open her up and see it can be...

iFixit Library Panasonic Lumix DMC-TZ10 Moderate 30 minutes - 1 hour Guide 12373
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

I decided to open her up and see it can be repaired - and it could! Apparently this guide also works for a similar camera, the Lumix Panasonic DMC-ZS10, with the exception that in Step 3 there are 4 extra screws to remove, two on each end.

Step 1

This shows the problem

  • One can clearly see the dust reproduced on the image
Step 2

Tools I used

  • Magnifying Glas
  • Electronics Screwdriver set
  • Cloth and Q-Tips
  • tweezers
  • My Swiss-Army Knife :-)
  • TIP! have a sheet of letter paper to put the parts on as you remove them. You can keep them in removal order so it's easy to reverse the sequence on reassembly.
Step 3

Front panel removal

  • Remove Bottom screws
  • 3 visible in the picture
  • 2 off screen
  • Only for the DMC-ZS10: there are 4 extra screws to remove, two on each end.
  • Remove front panel
Step 4

Battery Cover

  • This Step is optional and provided simply for better handling.
  • slide pin to side
  • use small pliers to pull or pin to push
  • Caution
  • Don't lose the spring!
  • remove cover
Step 5

Lift back cover

  • Carefully lift the cover slightly upwards
  • Remove the switch
  • It's only secured with a clip at one side and might fall off during handling, if not removed now. However, this step is - optional-
  • Lift sideways and remove the two PCB connectors
  • Best use your fingernail or a soft plastic spudger to gently flip the black plastic on the side of the connector to the right until it flips over
  • Then gently pull the PCB to the left outwards without damaging it or bending it too sharply
  • Remove back cover completely
Step 6

Remove protective metal cover

  • Remove screws
  • Lift metal clamps gently
  • Remove metal cover
Step 7

Remove Imaging Chip

  • Remove screws holding the Chip assembly
  • Remove PCB Connector (optional) or simply and carefully flip the assembly over
  • Now the Chip with its protective cover is accessible
  • Note: The last two images show the whole imaging subassembly removed - this is NOT required if you only want to access the chip
Step 8

Clean the protective cover

  • Clean the protective cover (without any cleaning fluid so to not leave residue on the glass)
  • Use a Q-Tip or a lint-free cloth like for glases and check with the magnifier for success
  • This is a delicate procedure that requires much care and a dust free environment