FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Rug Doctor Pump Replacement

If the Rug Doctor is not spraying properly, you...

iFixit Library Rug Doctor Carpet Cleaner Wide Track 95373 2016 Moderate 20 - 50 minutes Guide 123850
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

If the Rug Doctor is not spraying properly, you may need to replace the pump . The Mighty Pro and the X3 models have one pump , while the Wide Track (WT) model has two identical pumps running in parallel. This guide is written with the Wide Track model, but can be used for any of the three models. Optional tools: Straight edge cutters/pincers instead of hose clamp pliersClamp cutter/removal toolHair dryer/heat gun

Step 1

Diagnosis

  • Before you begin, determine if the pump(s) require replacement. Fill the reservoir with some water, turn the Rug Doctor on to the carpet mode and press the spray button.
  • For single-pump models (Mighty Pro, X3), if the Rug Doctor does not spray at all, the pump requires replacement.
  • If it sprays inconsistently, check the spray nozzles for clogs first.
  • For the Wide Track model, if the Rug Doctor does not spray at all, both pumps require replacement.
  • If water splashes out of the nozzles for the Wide Track model but does not spray adequately, check the spray nozzles for clogs first.
  • If the nozzles are clear, one of the two pumps may be defective, not supplying sufficient pressure to the nozzles. If possible, replace both pumps.
  • If you need to determine which of the two pumps requires replacement, switch the Rug Doctor on to the upholstery mode. Do not disconnect the quick-connect for accessories. If water splashes out of the nozzles like the carpet mode, replace the front pump.
  • If water does not splash out of the nozzles in accessory mode, replace the rear pump.
Step 2

Pump

  • Before you begin disassembly, make sure that the Rug Doctor is not plugged in and that all reservoirs are empty of liquids.
  • Use pliers to grip and wiggle the axle hub cap to loosen it.
  • Pull the axle cap off.
  • If you are having trouble, pry under the cap to loosen it from the axle.
Step 3

Repair step

  • Pull the wheel off of the axle.
  • Pull the other wheel with the attached axle out of the body.
  • Re-assembly tip—to reinstall the wheels and axle:
  • Slide the axle and wheels back onto the Rug Doctor.
  • Center a replacement axle hub cap over the exposed axle end.
  • Use a mallet to tap the hub cap in place. It should not feel loose on the axle.
Step 4

Repair step

  • Unclip the clear hose from the back of the Rug Doctor.
Step 5

Repair step

  • Remove the eight 15.1 mm long Phillips machine screws securing the bottom pan.
Step 6

Repair step

  • Remove the five 15.1 mm long Phillips machine screws securing the back plate.
  • During re-assembly, over-tightening these screws may crack the plastic plate.
Step 7

Repair step

  • Beginning from the bristle end, carefully pull the bottom pan away from the body, to gain access to the pumps.
  • This will loosen the front metal blade. It may be helpful to temporarily reinstall a screw to hold it in place while you work.
Step 8

Repair step

  • Carefully note the pump direction indicated by the arrow on its label. The replacement pump must be installed in the same direction as the original.
  • If you are working on the Wide Track model, determine which pump(s) you are replacing as well as their direction:
  • The front pump
  • The rear pump
Step 9

Repair step

  • Remove the crimped hose clamps securing from each end of the pump you are replacing.
  • You can use a clamp removal tool to cut the clamps.
  • Alternatively, use pliers to unlatch the small retaining tab on the clamp.
  • Pry the clamp apart to loosen it.
  • Use your fingers or pliers to pull the hoses off of the pump nozzles.
  • The hoses will leak liquids when pulled out.
  • This will take significant force. If you are having trouble, heat the hose ends with a hair dryer or heat gun, and try again.
Step 10

Repair step

  • Re-assembly tip—to reinstall the crimp-style hose clamps:
  • Slide the clamp onto the hose, leaving 1/2" of hose at the end.
  • Use hose clamp pliers or straight edge cutters to squeeze and crimp the clamp ears.
Step 11

Repair step

  • Cut the zip ties holding the bundle of wires together.
  • Carefully trace the two wires coming out of the pump you are replacing.
  • The pump wires should connect to a black wire and a white wire.
  • There may be a diode attached in-line on the red wire.
  • Disconnect the pump by pulling the wire terminals apart. This may take significant force. Pull at the terminals, not the wires.
  • If there is an in-line diode, disconnect and remove it. Do not use it with the replacement part.
Step 12

Repair step

  • Re-assembly tip—when you re-wire the replacement pump, attach the included fusible link to the longer, thicker black wire.
  • Do not use the previous pump's in-line diode.
  • Re-connect the pump's wires to the Rug Doctor's black and white wires.
  • The fusible link should connect to the Rug Doctor's black wire.
Step 13

Repair step

  • Pull the rubber mount away from the pump and slide it over the pump nozzle.
Step 14

Repair step

  • Slide the pump out of the rubber mount.
Step 15

Repair step

  • Remove the pump.
  • When installing the replacement pump:
  • Remove the orange caps from the nozzles.
  • Make sure that the pump is installed in the correct direction.
  • Check that the nozzles are pointed towards the back of the machine.
  • The replacement pump may not sit as snugly in the rubber mount as the original. This is normal.