Step 1

Repair step

  • Remove the 2 Phillips screws, then pull off the white rubber feet and open the triangular screws underneath. Special tool.
  • The bottom can be pulled off. Remove the cable holder to be able to work better
  • Unscrew the two circuit boards and disconnect the motor and the sensor cable. The sensor cable with 2 wires remains on the small circuit board.
Step 2

Repair step

  • Unsolder SR3100 diode and solder in new diode. 3 A 100 V. The diode had continuity and at the small control board was only 2.5 V at the red and black cable.
  • The temperature sensor resistor is marked green. This has about 95k ohm at room temperature.
  • I also checked the blue marked temperature fuse for continuity and the purple marked contact switch.