Before you begin

This guide will help you replace a faulty or broken trigger switch assembly that may be on this Ridgid GEN5X R8653 circular saw. The switch is a critical component of this power saw. The symptom of a faulty trigger switch is failure of the saw to operate even with a fully charged battery in good condition . For further information check out our troubleshooting page. Please be sure to take all of the precautionary steps to ensure your safety while working on this device.

Step 1

Repair step

  • Always disconnect battery and remove saw blade before working on this or any other circular saw. Failure to do so may result in damage or injury!
Step 2

Repair step

  • Remove the supplied Allen wrench from it's nesting space in the front of the handle.
  • Remove one 7mm T20 torx screw to remove cut depth lever located behind the motor shroud on the left side of the saw.
  • Slowly remove lever from saw ensuring not to lose the compression spring between the lever and retaining screw.
Step 3

Repair step

  • Loosen the angle cut guide lever by pulling it counter clockwise and tilt the base assembly to allow easy access to all housing assembly screws.
Step 4

Repair step

  • Remove six T20 Torx 20mm screws from the upper housing.
  • Remove three T20 Torx 32mm screws from the upper housing
Step 5

Repair step

  • Gently lift away upper housing to expose the internal parts of the saw.
Step 6

Repair step

  • Remove the Phillips #2 screw holding the switch assembly to the lower housing.
  • Remove the four Phillips #2 screws that hold the wires onto the switch.
  • Lift the switch out from the casing.
  • Ensure the two red wires are mounted closest to the trigger mechanism during reassembly.