Before you begin

If the right or left mouse button is not responsive, the micro switch might need replacement. This guide will list all required steps to properly replace the left and/or right mouse button micro switches from the Razer Naga Trinity.

Step 1

Repair step

  • Remove the interchangeable side plate.
Step 2

Repair step

  • Remove the mouse's feet using the opening pick.
Step 3

Repair step

  • Remove the four 6mm screws by using a JIS #1 screwdriver.
Step 4

Repair step

  • Separate the top mouse housing from the bottom mouse housing using the opening pick.
  • Be careful not to tug too hard on the ribbon connector.
Step 5

Repair step

  • Unlock the ribbon connector that is held down by the main board clips using the spudger's pointed end.
Step 6

Repair step

  • Remove the side housing using the opening pick.
Step 7

Repair step

  • Remove the top housing LED 3-Pin connector that is near the main board.
Step 8

Repair step

  • Remove one 4mm black Phillips #000 screw from the left side of the mouse holding the scroll wheel LED controller board.
  • Then pull the LED controller board upwards and out.
Step 9

Repair step

  • Pry and remove the scroll wheel feedback bar from its hold-down clips using the hook end of a halberd spudger.
Step 10

Repair step

  • Remove the scroll wheel feedback bar from the scroll wheel by holding down the spring and using angled tweezers to remove it from its placement.
Step 11

Repair step

  • Remove the scroll wheel optical encoder 3-pin connector from the main board by wiggling the connector upwards.
Step 12

Repair step

  • Using the opening tool, pry the black bracket holding the scroll wheel in place backwards until the scroll wheel housing pops out.
Step 13

Repair step

  • Remove the USB Type A to 5-pin connector from the main board by pinching and pulling upwards.
Step 14

Repair step

  • Remove four 3mm JIS #1 screws holding the main board.
Step 15

Repair step

  • Place the tip of the soldering iron onto the micro switch contact pins.
  • Work around the micro switch pins while prying the switch with an opening pick.
Step 16

Repair step

  • Remove and replace OMRON D2FC-F-K(50M) micro switch.
  • Solder all three micro switch pins with soldering iron.
  • Ensure the micro switch is bonded by performing a tug test.