Guide overview

Before you begin

This guide will show you how to disconnect the control link and remove the handle assembly of a Clarke EZ-8 Floor Sander.

Step 1

Disconnect all power cables

  • Before you begin your repair, disconnect all power cables to reduce the risk of short circuits and electric shock.
Step 2

Remove the dust bag

  • Pull on the dust bag to remove it from the dust tube.
  • If the dust bag doesn't slide off easily, gently twist it back and forth while pulling to free it from the tube.
Step 3

Remove the dust tube

  • Pull up on the dust tube to remove it from the sander.
Step 4

Disconnect the control link arm

  • Slide the collar on the control link arm up until the two halves of the arm detach from one another.
Step 5

Repair step

  • Pull up on the latch at the bottom of the handle assembly, then remove the retaining plate from its slot in the handle.
Step 6

Remove the handle

  • Pull up on the handle assembly and remove it from the sander.