Changing the Bath NF SIRYO CHROME thermostatic cartridge

This guide will help you change out the Bath NF...

iFixit Library Thermostatic faucet Moderate No estimate Guide 129899
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This guide will help you change out the Bath NF Siryo Chrome Thermostatic Cartridge

Step 1

Access to the thermostatic cartridge

  • WARNING: Before any intervention, make sure that the inverter is in the "OFF" position and close the water supply to the meter.
  • Using a flat screwdriver, unclip the cover to access the handle fixing screw.
  • Unscrew the fixing screw counterclockwise.
Step 2

Dismantling the thermostatic handle

  • Before disassembling, check that the mark on the mixer tap is aligned with the "38°" position, then remove the handle.
  • ATTENTION: before extracting the stop ring (38°), check that the two notches are aligned with the mark on the mixer
  • Extract the thrust ring
Step 3

Removing the thermostatic cartridge

  • Unscrew the thermostatic cartridge anti-clockwise using a 21 wrench.
  • Extract the cartridge by hand.
Step 4

Reassembly

  • Insert the thermostat in the mixer body.
  • Screw in clockwise by hand.
  • Finish the tightening using the spanner 21.
  • ATTENTION: The tightening torque must not exceed 10Nm. We therefore advise you to use a torque wrench so as not to damage the thread of the thermostatic cartridge.
Step 5

Replacing and adjusting the stop ring

  • Position the two lines marked on the stop ring facing the point of the mixer tap.
  • Turn on the water supply to proceed with the adjustment step.
  • Turn the diverter handle to run the water, then place a thermometer under the flow to check the correct temperature, which should be 38°.
  • If the temperature is not 38°, adjust by turning the wheel clockwise to decrease the temperature (-°C).
  • And counterclockwise to increase the temperature (+°C).
Step 6

Replacing the handle

  • Align the reference point on the mixer body with the 38° mark on the handle.
  • Tighten the handle fixing screw using a Phillips screwdriver in a clockwise direction.
  • Replace the cover.