Auto-Feeder Disengagement

Follow this guide to disengage the Auto-Feeder...

iFixit Library Electric Eel Drain Cleaner Z5K12IC75AF 2013 Very easy 1 minute Guide 131140
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Follow this guide to disengage the Auto-Feeder on your Electric Eel Drain Cleaner Z5K12IC75AF so the cable can pass through freely or removed.

Step 1

Remove the Guide Spring

  • Unplug your drain cleaner before starting this guide. Because this device may have been used in a septic setting, it should be cleaned and disinfected as much as possible before disassembly.
  • Wear gloves to protect your hands from injury when handling the cable.
  • Ensure the cable is completely retracted into the auto-feeder.
  • Twist the guide spring counter-clockwise to unscrew it from the auto-feeder.
  • Remove the guide spring.
Step 2

Release the Tension Spring

  • Unscrew the tension knob to loosen the tension spring in the top feeder assembly.
Step 3

Set the Feeder in Neutral Position

  • Set the feeder adjustment knob in the neutral position, in between the "FWD" and "REV" positions.
Step 4

Disengage the Top Bearing

  • Push the top control finger up as far as possible.
  • This disengages the top feeder assembly and allows the cable to freely move through the feeder. The finger may fall back down on its own and restrict cable movement. If this occurs, simply push the finger back up.