FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Siemens Surpresso Compact drainage valve replacement

If the coffee doesn´t flow right into your cup,...

iFixit Library Siemens Surpresso Compact Moderate No estimate Guide 131909
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

If the coffee doesn´t flow right into your cup, but in the drawer the drainage valve might be broken. You can replace the gaskets in the valve or simply the whole valve. These instructions may also help with other Siemens/Bosch models and with coffee makers from Nivona, Melitta, and Miele—they have a very similar design.

Step 1

Repair step

  • Unplug your coffee maker!
  • Remove the water container, the brew group and the drip tray with pomace container.
  • Using a spoon, remove as much of the coffee beans as possible from the coffee bean container.
  • Depending on the model, additional sensors with cables may be installed on the top and side panels. You have to remove these before you can completely remove the housing parts.
Step 2

Repair step

  • Remove the two Torx T10 screws on the top.
Step 3

Repair step

  • Remove seven T10 Torx screws on the back.
  • The two screws at the bottom of the front can remain.
Step 4

Repair step

  • Press with a flat-head screwdriver into the openings on the side with the water tank. This releases the latches on the top.
  • Press the flat-head screwdriver into the opening on the side with the brew group. This will release the last notch on the top.
  • Lift the top off.
  • On some models, a cable leads to the sensor on the powder tray. Unplug the connector on this cable first.
Step 5

Repair step

  • Slide the side section of the brewing unit about 2 cm to the rear. This sometimes gets stuck and may require some force to remove.
  • Remove the two tabs from the power switch.
  • Take off the side panel with the brew group.
Step 6

Repair step

  • Do the same with the panel on the other side.
  • To remove the water tank hose simply pull it of the pump.
  • Remove the side panel.
Step 7

Repair step

  • Rotate clockwise the expansion box about 60 degrees and pull it out.
  • The expansion box is frequently filled with coffee oils or grounds. Clean it from time to time. It can easily be separated into two halves.
Step 8

Repair step

  • The drainage valve is directly plugged to the gear drive. The drive is fixed with five Torx T10 screws on the center panel behind the brew group.
  • Remove the five Torx T10 screws holding the gear drive in place.
Step 9

Repair step

  • Push the gear drive outwards to the left. Pay attention, several cables might get caught.
  • Lay the gear drive on its side. Loosen the upper water connector by pulling the clamp and than sliding off the hose. Mind the O-ring on the end of the hose, replace it if necessary.
Step 10

Repair step

  • The drainage valve is exposed.
  • Remove the spring on the lower end of the valve.
  • Lift the upper gray part of the valve. Push the lower part of the valve a little bit downwards und lift it out.