Dewalt Nailers DCN21PL 2018 Main Electronics Replacement

This guide shows how to remove or replace the...

iFixit Library Dewalt Nailers DCN21PL 2018 Moderate No estimate Guide 133998
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This guide shows how to remove or replace the main board electronics in a Dewalt DCN21PL Nailer.

Step 1

Remove the battery

  • Before you begin the repair, remove the battery from the device.
Step 2

Remove casing screws

  • Use a T10 driver to remove the four screws securing the bottom half of the casing.
  • Remove the four T10 screws securing the top half of the casing.
Step 3

Remove the magazine

  • Use a T10 driver to remove the screw securing the magazine to the base.
Step 4

Repair step

  • Pull the magazine down and away to unlatch and release it from the nailer.
Step 5

Remove framing hook

  • Use a T15 driver to remove the framing hook retaining screw.
  • Remove the hook.
Step 6

Remove hook clamp

  • This step may require a lot of force.
  • Use your two thumbs to firmly spread the metal hook clamp apart while slowly pushing it forward off the handle.
  • When this clamp is being removed, it has a tendency to launch off of the handle after you release tension.
Step 7

Repair step

  • Use a sharp blade to slice the label underneath the battery mount to disconnect the two halves of the case.
  • Always cut away from you or others around you.
Step 8

Repair step

  • Use a T20 driver to remove the two screws securing the two halves of the case to the front assembly.
Step 9

Remove return system

  • Use the provided 3.5 mm hex key to remove the two return system bolts on either side of the nailer.
Step 10

Repair step

  • Grab the end cap and slide the return system assembly out of the back of the nailer to remove it.
Step 11

Repair step

  • Use a small flathead screwdriver in the gap between the two halves of the casing near the trigger to pry the two halves apart.
Step 12

Repair step

  • Use a small flathead screwdriver near the top seam to continue prying the case apart .
Step 13

Remove right half of case

  • Once loose, lift up to remove the right half of the clamshell case.
Step 14

Remove lens cover

  • Remove the plastic lens cover.
Step 15

Remove board and switches

  • The two switches and four detent springs are only held in place by the plastic casing, so they may fall out when you remove the board—this is fine.
  • Grasp either side of the main circuit board and slowly pull it up and out of the slot in the casing.
  • Reassembly tip: note the correct location and orientation of the two switches and their detent springs.
Step 16

Remove trigger lock

  • Pull up on the trigger lock to remove.
Step 17

Remove left half of case

  • Flip the nailer over.
  • Remove the remaining clamshell casing.
Step 18

Remove main electronics

  • Use wire snips to cut the small black cable tie securing the four main board wires together.
Step 19

Repair step

  • Pull the white plastic actuator straight up off its axle to remove.
Step 20

Repair step

  • Insert the point of a pick tool into the push-in connector's inlet hole, which has the main board wire plugged into it.
  • With the pick tool still inserted, pull the red main board wire out of the push-in connector.
  • Make sure you choose the inlet that connects to the main board, not the solenoid.
  • Repeat this same process for the black wire and other push-in connector.
Step 21

Repair step

  • Use a T20 driver to remove the following screws:
  • Two 15 mm-long board retaining screws, one on either side.
  • Three 10 mm-long motor wire screws.
Step 22

Repair step

  • Slide the board off its guide pin to remove.
  • Reassembly tip: make sure the actuator plunger lines up with the guide hole on the main board housing.