After what I suspect was a power surge a while back, my nice $450 electrostatic air cleaner became non-functioning, I was determine to find out why. I have to give GeneralAire credit, they actually have a usable troubleshooting section of their manual to help isolate functions and problems, and a part list to identify things, unfortunately the parts that needed replacement were more than an entire new unit… so I dug in a little deeper.

Step 1

What seems to be the problem?

  • WARNING: This unit can contain high voltages on the order of 6000VDC, pay attention to what you are doing.
  • Disconnect unit power wait 15 minutes for voltage to dissipate and open the top cover.
  • Disconnect the 24VAC power to the high voltage PCB to prevent generating high voltages.
Step 2

Indicator Testing

  • The first was to test the front panel LED indicator to rule out stupidity, but I had a good idea it went well beyond an indicator light as the filter had not been getting dirty.
  • This was a simple test, touch a 9V battery in the correct polarity to the red and black wires coming off the HV board, the indicator should light up brightly, and it did.
Step 3

Transformer Testing

  • Making sure the yellow and blue wires from the 24VAC transformer are off the HV board, clip on a volt meter and energize the unit with the front panel switch. I should have seen voltage there for about 5 seconds as the air proving switch turned on then off, but got nothing.
  • Turn off the 120VAC power switch.
  • Per the manual, I moved back to the air proving switch, a small board with a PTC thermistor and a triac that energize to provide 120VAC to transformer. With output lead 4 disconnected, connect he volt meter between pin 1 and 4.
  • Energize the unit once again. Still only a few 100mV. Carefully check that there is 120VAC on the incoming posts 2 & 3, yep it's there.
  • Turn off the 120VAC power once again.
Step 4

Debugging

  • At this point, I had three suspects, the transformer, the air proving switch, and after closer inspection, I saw a brown discoloration on one of the high voltage capacitors.
  • I decided to start with the transformer. After removing it from the unit, I checked the secondary and measured about 7 Ohm, reasonable. The primary was open, just to make sure I slowly opened the primary coil and after getting back to the winding, didn't see anything obvious, but it was still measuring open.
  • On removing the air proving switch, the thermistor checked out at about 1kOhms and responded with a squirt of canned air. All the discretes checked out except for the triac.
Step 5

Reckoning

  • At this point I needed:
  • Air Proving Switch $76.38
  • Transformer $54.30
  • Power Control Board $310.27
  • New unit: $461.99
Step 6

New Parts

  • Looking up the individual parts:
  • Triac TO220AB $1.22
  • 50VA transformer $22.70
  • 2000pF cap, 6kV $0.77 each
  • Total parts plus some spares and a thermistor $38.60
  • Looks like I'm fixing this thing.
Step 7

Swap Out Parts

  • Just some careful desoldering with wick and wiggles.
  • All the old parts laid out.
Step 8

Final Testing

  • Reverse the order of testing:
  • Connect the air proving switch and verify voltage at pins 1 & 4.
  • Connect the transformer and verify 24VAC out when energized and the air proving switch is cold.
  • DO NOT USE OR MEASURE THE HIGH VOLTAGE BOARD WITH ANYTHING OTHER THAN NON CONTACT VOLTAGE PROBE.
  • With everything connected, powered up the unit and watched the indicator come on and go off. I turned on the fan to the air unit and the indicator came back on and very carefully bringing the voltage probe near the HV lines, I got some nice chirping.