Before you begin

Use this guide to replace a worn-out or dead battery in your Fitbit Ionic.If your battery is swollen, take appropriate precautions. For your safety, discharge your battery below 25% before disassembling your Fitbit Ionic. This reduces the risk of a dangerous thermal event if the battery is accidentally damaged during the repair.You’ll need replacement adhesive to reattach components when reassembling the device.

Step 1

Repair step

  • Before starting, take your Fitbit Ionic off the charger and power it down.
  • Feel free to attach or remove the watch band as needed to provide more control as you make repairs.
Step 2

Repair step

  • Heat an iOpener and apply it on the display for at least two minutes to soften the adhesive underneath.
  • The adhesive of the Fitbit Ionic is very strong. You may need to reheat the iOpener and repeat this procedure several times until the display adhesive gets loose enough.
Step 3

Repair step

  • Insert a technician's razor with a flat blade into the small gap between the watch case and the display.
  • Cut through the adhesive on the upper side of the Fitbit Ionic.
Step 4

Repair step

  • Use a technician's razor with a flat blade to pry up the top edge of the display and create a small gap.
Step 5

Repair step

  • Insert two opening picks underneath the top left and the top right corner.
  • Leave the opening picks in place to prevent the adhesive from resealing.
  • Remove the razor blade.
Step 6

Repair step

  • Insert a third opening pick underneath the top right corner and slide it along the right edge of the display.
  • Leave the opening pick in the bottom right corner to prevent the adhesive from resealing.
  • If cutting becomes too difficult, reheat and reapply the iOpener.
Step 7

Repair step

  • Insert a fourth opening pick underneath the top left corner and slide it along the left edge of the display.
  • Leave the opening pick in bottom left corner to prevent the adhesive from resealing.
  • Do not remove the display assembly all the way yet—it's still connected to the mainboard.
Step 8

Repair step

  • Carefully fold the display assembly in the direction of the bottom edge.
Step 9

Repair step

  • Use the flat end of a spudger to loosen and pry up the mildly glued NFC antenna.
  • Carefully fold the NFC antenna in the direction of the upper edge of the watch.
Step 10

Repair step

  • Carefully fold the display assembly onto the upper side of the watch.
  • Take care not to pull or bend the cables too much—they are still connected to the mainboard.
Step 11

Repair step

  • Remove the Torx T2 screw (3.65 mm length) on the bottom left corner.
Step 12

Repair step

  • Use a pair of tweezers to remove the metal shield covering the battery flex cable.
Step 13

Repair step

  • Use a spudger to pry up and disconnect the battery flex cable.
Step 14

Repair step

  • Fold the display assembly back to its original position.
Step 15

Repair step

  • Remove the two Torx T2 screws (3.65 mm length) from the top edge of the watch.
Step 16

Repair step

  • Use a pair of tweezers to remove the metal cover.
Step 17

Repair step

  • Use a spudger to pry up and disconnect the NFC antenna.
  • Remove the NFC antenna.
Step 18

Repair step

  • Use a spudger to pry up and disconnect the two display cables from the motherboard.
Step 19

Repair step

  • Remove the display assembly.
  • If possible, turn on your Fitbit Ionic and test your repair before installing new adhesive and resealing.
Step 20

Repair step

  • Remove the Torx T2 screw (3.65 mm length).
Step 21

Repair step

  • Use a spudger to pry up and disconnect the heart rate sensor from the motherboard.
Step 22

Repair step

  • Insert a spudger into the gap between the watchcase and the upper edge of the motherboard.
  • Use the spudger to pry up the motherboard.
  • Avoid damaging the battery and heart rate sensor cables during the motherboard removal procedure.
  • Remove the motherboard.
Step 23

Repair step

  • Remove the four Torx T2 screws (1.8 mm length).
Step 24

Repair step

  • Insert the flat end of a spudger between the watchcase and the battery on the top edge of your Fitbit Ionic.
  • Use the spudger to pry up the battery.
Step 25

Repair step

  • Remove the battery.