Honda 6500 Watt Generator EG6500CL AT Rear Generator Housing Replacement

This guide shows how to remove the rear...

iFixit Library Honda 6500 Watt Generator EG6500CL AT Moderate 10 - 45 minutes Guide 135762
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This guide shows how to remove the rear generator housing as well as the rear bushings for the Honda 6500 Watt Generator EG6500CL AT. This procedure shows how to remove the rear bracket without removing the generator from the frame. You will need some wooden blocks that are about 2.5 inches tall to support the generator.

Step 1

Repair step

  • Before you work on the device, make sure to switch the engine off.
  • Switch the circuit breaker off.
Step 2

Disconnect the spark plug

  • Grab the plastic housing at the end of the spark plug wire.
  • Pull firmly to disconnect the wire from the spark plug.
Step 3

Repair step

  • Twist the fuel valve clockwise into the cutoff position.
Step 4

Remove the generator cover

  • Use a Phillips screwdriver to remove the two screws securing the generator cover.
Step 5

Repair step

  • Remove the generator cover.
Step 6

Remove the brush assembly

  • Squeeze and disconnect the stator connector from the wiring harness.
Step 7

Repair step

  • Use a 10 mm socket to remove the bolt securing the brush assembly.
  • Pull the brush assembly out slightly from its recess.
Step 8

Repair step

  • Disconnect the two spade connectors from the brush assembly.
Step 9

Repair step

  • Remove the brush assembly.
  • During reassembly, use the second photo as reference for how to wire the brush assembly.
Step 10

Loosen the rear generator housing

  • Use a 10 mm socket to remove the four long bolts securing the generator cover to the generator assembly.
  • During reassembly, tighten these bolts to 7 ft-lb (10 N-m).
Step 11

Repair step

  • Use a 14 mm socket to remove the rotor bolt from the generator assembly.
  • This bolt may be difficult to loosen. If you have trouble removing the bolt, use an impact wrench or breaker bar.
  • During reassembly, tighten this bolt to 33 ft-lb (44 N-m).
Step 12

Repair step

  • Remove the rotor bolt and washer.
Step 13

Repair step

  • Use an 8 mm socket to remove the four nuts securing the wiring harness to the terminal.
  • Remove only the top nut from each terminal post.
  • Be careful not to lose the crush washers behind them.
  • Remove the wiring harness wires from the terminal.
Step 14

Reassembly tip

  • During reassembly, use these photos as a reference for how to re-stack the terminal posts. From the terminal base to tip:
  • Base washer
  • Crush washer
  • Stator wire connector
  • Nut
  • Wiring harness connector
  • Crush washer
  • Nut
Step 15

Repair step

  • Use an 8 mm socket to remove the three bolts securing the wiring terminal and harness.
  • Remove the Phillips screw securing the harness ground.
  • Loosen the wiring terminal and harness from their resting positions.
Step 16

Repair step

  • Use pliers to release the cable tie securing the wiring harness to the generator assembly.
Step 17

Loosen the mounting bolts

  • Carefully tilt the rear of the generator upwards to access the under-frame bolts.
  • Use a 12 mm socket to remove the two bolts underneath the frame, which secures the rear generator housing.
Step 18

Repair step

  • Removing these nuts give the generator assembly enough slack to remove the rear bushings.
  • Use a 14 mm socket to remove the mounting nut next to the emissions canister.
  • Use a 14 mm socket to remove the mounting nut near the oil filler hole.
Step 19

Repair step

  • Use a 14 mm socket to remove the two nuts securing the rear housing to the bushings.
  • During reassembly, be sure to re-attach the ground terminal to the left bushing.
Step 20

Remove the rear bushings

  • In these photos, the generator frame is propped on some blocks for ease of access. You do not need to do this for the procedure.
  • Tilt the generator assembly by lifting the rear housing slightly.
  • Place support blocks underneath the silver generator housing to support the generator assembly.
  • The generator weight should rest on the support blocks and no longer on the rear bushings.
  • Do not support the generator by the black stator cover.
Step 21

Repair step

  • Lift the rear generator housing up as far as you can and maneuver the left bushing out of its socket.
  • Remove the left bushing.
Step 22

Repair step

  • Repeat the previous step to remove the right bushing from its socket.
Step 23

Remove the rear generator housing

  • Remove the rear generator housing from the generator assembly.