Dexter 900W Corded Hammer Drill - 900ID2.5 Output Shaft Replacement

This guide shows how to replace the output...

iFixit Library Perceuse à Percussion Filaire Dexter 900W - 900ID2.5 Easy 10 minutes Guide 135899
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This guide shows how to replace the output shaft of a Dexter 900ID2.5 900W corded hammer drill. You must disconnect the drill from the power supply before opening it. The internal chuck screw turns to the right to unscrew.

Step 1

Unplug

  • Before you begin, remember to disconnect the mains plug.
Step 2

Repair step

  • Remove the handle from the machine.
Step 3

Repair step

  • Open the chuck to the maximum to gain access to the inner screw.
Step 4

Repair step

  • Lock the chuck using a 15 spanner (thickness 3), then unscrew to the right with a pz3 screwdriver.
Step 5

Repair step

  • Using a pair of pliers, unscrew the chuck.
Step 6

Repair step

  • Using a screwdriver or screwdriver, unscrew and open the device.
Step 7

Repair step

  • Unscrew the four screws.
Step 8

Repair step

  • Using a screwdriver, lift the spring of the two brushes.
Step 9

Repair step

  • Remove the output shaft.
  • Before replacing the new part, be sure to re-grease.
Step 10

Repair step

  • Reposition the brush springs.
Step 11

Repair step

  • Then retighten the four screws.
Step 12

Repair step

  • Before closing, check that no cable is blocked and that each part is in its place.
  • Tighten the screws to close the device.
Step 13

Repair step

  • Replace the chuck.
Step 14

Repair step

  • Screw the chuck back on by hand.
  • Then using a screwdriver replace the screw, and screw to the left.
Step 15

Repair step

  • Finally replace the handle.