FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

General Pipe Cleaners Drain Cleaner EJB 2014 Motor Assembly Replacement

Use this guide to replace the motor assembly in...

iFixit Library General Pipe Cleaners Drain Cleaner EJB 2014 Moderate 5 - 15 minutes Guide 137203
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Use this guide to replace the motor assembly in a General Pipe Cleaners Drain Cleaner EJB 2014.

Step 1

Repair step

  • Before you begin, make sure the drain cleaner is disconnected from power.
  • Loosen the belt guard knob enough to be able to slide the belt guard toward the front of the drain cleaner.
Step 2

Repair step

  • Slide the belt guard toward the front of the drain cleaner and off of the motor.
Step 3

Repair step

  • Push down on the motor to take tension off of the belt.
  • The motor mount is spring-loaded to keep tension on the belt.
  • Lift the belt off of the motor pulley and remove it from the motor.
Step 4

Repair step

  • Use two 1/2 inch wrenches to remove the four nut and bolt sets securing the motor to the drain cleaner.
  • During reassembly, make sure that the belt pulley on the motor is lined up with the belt groove on the cage before tightening the bolts.
Step 5

Repair step

  • Remove the motor assembly.