FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

DeLonghi Coffee Maker burr set replacement

These instructions show how to replace the...

iFixit Library DeLonghi Coffee Maker Moderate No estimate Guide 139753
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

These instructions show how to replace the grinding burr for a DeLonghi cone grinder. The grinding burrs are not available as original DeLonghi parts, but are available from third-party manufacturers. Pay attention to the exact model designation. Compare the spare part and make sure that the ring burr has three flattened sides (not two, as e.g. with Jura). Also take a look at our wiki DeLonghi grinder jams.

Step 1

Repair step

  • If the bean hopper is still attached, it must be removed.
  • Use a pointed tool to remove the cap on the adjustment dial.
Step 2

Repair step

  • There is a Phillips screw underneath. Unscrew it.
  • Note the position and pull the dial upwards.
  • Pull the bean container upwards.
  • On some models, there are two more Phillips screws in the bean hopper.
Step 3

Repair step

  • Mark the settings of the wheels with a pencil.
  • Use a spatula to loosen the two detents on the sides.
  • Pull off the red silicone seal.
Step 4

Repair step

  • Lift off the white plastic ring.
  • Turn the white ring with the ring gear counterclockwise as far as it will go.
  • The grinding ring is free and you can lift it out upwards.
Step 5

Repair step

  • The grinding ring can be completely removed from the plastic holder. To do this, lift the three detents to the side and push the ring out.
  • The ring has three flattened sides. Unfortunately, such a ring is not commercially available anywhere. If it is still good, you may be able to use it in another mill.
Step 6

Repair step

  • The grinding cone is fastened with a Torx T20 screw with left-hand thread.
  • Unscrew the screw clockwise, i.e. the wrong way round.
  • When assembling, make sure that the screw with its fastening part fits exactly into the intended groove.
Step 7

Repair step

  • Carefully lift the grinding cone upwards.
  • This grinding cone is the same as on the Jura and can now be replaced.
  • There are three metal balls on springs under the grinding cone. They are stuck in three sleeves in the plastic driver. Make sure that none of these parts get lost.
  • Lift the driver up and out.
  • Now you can clean all parts thoroughly.
  • When reassembling, make sure that the metal balls fit into the corresponding recesses in the cone.