Step 1

Repair step

  • Remove battery, and the sticker underneath.
  • Picking a corner with a tweezer then grip and turn with the tweezer is a good way to remove the sticker.
  • Remove the two T5 torx screws.
  • Push firmly and turn to avoid slipping and stripping.
Step 2

Repair step

  • Using a pry tool, start near the strap and pry away grip portion until it starts to hinge from the top.
  • Carefully pull back and down to remove the grip, clearing the grip trigger's hinge.
Step 3

Repair step

  • Remove the two T5 torx screws below the trigger.
  • Remember to apply pressure when removing the screws.
Step 4

Repair step

  • Using a straight-edge, wedge the inner ring away from the outer starting at the seam to separate the sensor array. Pull the sensors down carefully.
  • Be careful. The sensors are attached by ribbon cabling and could be easily damaged. The safest pry location is near the seem towards the bottom.
  • While pulling down on the sensors, push the outer ring towards the buttons. A uncomfortable amount of force is required to separate.
Step 5

Repair step

  • Insert wisdom here.
Step 6

Repair step

  • Remove two T5 torx screws near the trigger to separate the cover for the buttons.
  • Hold the cover down while turning the controller upside down to avoid spilling the buttons.
  • Unscrew four T5 torx screws around the controller to separate the bottom PCB. One is facing outwards near the trigger. Three others are opposite from the battery compartment.
Step 7

Repair step

  • Lift the wires up, and then remove the handle. Make sure to disconnect the wire or you may sever it.
  • The PCB also serves as the surface for the spring backing the trigger. Re-inserting the PCB with the handle still attached (for instance when cleaning) will require a separate tool to push the spring back while positioning the PCB back into place.
Step 8

Repair step

  • Lift the flap to disconnect the circuit board from the body.
  • To disconnect the thumbstick, pull the black bar towards the thumbstick slightly to release the wires. Do not try to lift the 'flap' as isn't one!