MiTM Air Compressors AM1HE0205HD 2014 Regulator Replacement

Use this guide to remove or replace the...

iFixit Library MiTM Air Compressors AM1HE0205HD 2014 Moderate 10 - 30 minutes Guide 140882
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Use this guide to remove or replace the pressure regulator on a MiTM Air Compressor AM1HE0205HD 2014.

Step 1

Power off the compressor

  • Before you begin, ensure the device is powered down and cool to the touch.
  • Ensure the compressor is unplugged.
  • Flip the pressure switch lever up to the off position.
Step 2

Drain the air from the compressor

  • Pull the ring on the safety release valve away from the compressor tank to drain the air from the compressor.
  • Ensure all air is drained from the tank before beginning repairs.
Step 3

Remove the air hose quick-connect socket

  • Use a 3/4 inch wrench to loosen and remove the air hose quick-connect socket.
Step 4

Remove the pressure gauge

  • Use a 7/16 inch wrench to loosen and remove the pressure gauge.
Step 5

Remove the regulator

  • Use a 5/8" wrench to loosen the air tank nipple from the air tank enough to be able to rotate it with the regulator.
Step 6

Repair step

  • Rotate the regulator 180°, so the bottom of the regulator faces away from the compressor motor.
Step 7

Repair step

  • With a 5/8 inch wrench bracing the air tank nipple, use a 3/4 inch wrench to loosen and remove the regulator.
  • Make sure the nipple stays connected to the air tank.