Step 1

Description of the defect

  • This extractor hood was fabricated in 2010 and had been installed in 2011. Suddenly it no longer responds to the built-in buttons nor the remote. a strange "-I." symbol flashes on the screen
Step 2

Turn off the power supply to the device

  • Turn off the power supply to the unit by turning off the appropriate fuse or pulling out the appropriate plug.
Step 3

Remove the 3 filters

  • Open the cover and remove the filters as for ordinary maintenance.
Step 4

Unscrew the stainless steel cover plate by removing 5 screws

  • Remove the 4 stainless steel screws at the far corners of the stainless steel cover plate with a Torx T15 screwdriver. (Do not unscrew any other screws.) Finish with the fifth screw in the middle of the right side, on the side of the hood motor. The plate will come loose, pivot on the left side, and remain attached.
Step 5

Open the black plastic box

  • This box is attached to the inside of the stainless steel cover plate (step 4). On the 4 corners, unscrew the 4 black Phillips #1 screws and remove the cover. You may notice the large loose capacitor hanging down. (Do not remove it as high voltage remains on the contacts.)
Step 6

Maak 3 kabelbundels los van de sturingsplaat

  • Did you disconnect the power supply, as per step 2 ? If yes, unplug the 3 black power cables: 1 from the red connector and 2 from the large and small gray connectors. Push the locking tab of the cables slightly to the side to pull the cable off the connector.
Step 7

Unscrew the control board

  • Using a Phillips PH1 screwdriver, unscrew the 2 screws: upper left and lower right.
Step 8

Disconnect the ribbon cable connector

  • On the left side, pull the control panel slightly out of the black box. Carefully disconnect the flat-cable plug (which goes to the control buttons). Push the tabs on the side of the connector slightly to the side. The connector on the control panel is red and similar to the unused orange connector below it. Do not drop it.
Step 9

Is the capacitor on the control board leaking?

  • Take a closer look at the control module. Is the blue electrolytic capacitor leaking, like the one in the pictures? If so, go to step 10 (Lelon brand capacitors do start leaking more often.)
Step 10

Replace the control board or the capacitor on it

  • Buy a new control module from NEFF (€157). Or maybe you can use the more challenging solution: solder a new capacitor onto the board. Then be careful not to put the negative connection of the capacitor on the outside. Characteristics of the capacitor: 1000 uF, 25V, M-type (+/- 20%), 5 mm between connections (€ 0.92 for a Panasonic at Conrad).
Step 11

After assembly: restart the range hood

  • After connecting to the power supply, "-I." appears again. on the display. But this symbol no longer flickers thanks to the repair. Push the "+" button to make the unit work again and get a normal output on the display.
Step 12

After assembly: reboot the remote control

  • Disconnect the unit from the mains power again. Then hold down the "+" button on the remote control and connect the power. A long beep will follow as fastener. If you do not hear this within 30 seconds, repeat these steps.