Step 1

Remove the motor cover bolts

  • Before you begin, ensure the power cord is unplugged and the power switch is in the OFF position.
  • Use a 13 mm socket to remove the two bolts securing the motor cover to the frame.
Step 2

Remove the motor cover

  • Remove the motor cover.
Step 3

Remove the electrical panel

  • Use a Phillips screwdriver to remove the four screws securing the electrical panel.
Step 4

Remove the electrical panel

  • Remove the electrical panel.
Step 5

Remove the power cord fastener

  • Use a Phillips screwdriver to remove the two screws securing the fastener behind the strain relief fitting.
Step 6

Repair step

  • Remove the fastener.
Step 7

Disconnect the on/off switch

  • Use a pair of needle-nose pliers to disconnect the two black and white wires from the on/off switch.
  • You don't need to remove the blue or red wires from the switch.
Step 8

Disconnect the ground wire

  • Use a Phillips screwdriver to remove the screw securing the green ground wire to the bottom of the electrical box.
Step 9

Loosen the strain relief fitting

  • Use an adjustable wrench to remove the power cord's strain relief fitting cap.
Step 10

Repair step

  • Slide the cap off of the strain relief fitting.
Step 11

Remove the power cord

  • Feed the power cord and its black, white, and green wires out through the strain relief fitting.