FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Repairing Error 9E 09 on Fujitsu Siemens FibreCAT TX48 S2 or identical devices from HP and Dell

This problem occurs in older devices when the...

iFixit Library Fujitsu Siemens FibreCAT TX48 S2 bzw. baugleiches Geräts von HP und Dell Moderate No estimate Guide 143640
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This problem occurs in older devices when the gears used in the elevator break due to material fatigue, causing them to jam. The break is usually difficult to detect on the installed device and typically occurs on one of the gears on the transfer axis.

Step 1

Set up in a stable position

  • Place the device on a flat surface (table) in a stable position using the felt feet on all corners. To open the housing, remove the top cover.
Step 2

Remove the cover

  • To do this, remove 3 types of screws all around using a TX10 screwdriver:
  • 2 countersunk screws at the front top
  • On the sides at the front, one round-head screw each on the left and right, and one at the back. On the side, the round-head screw located behind the middle with the rail guide sleeve.
  • At the back, release all outer mounting screws of the components (power supply unit(s) and expansion cards), as well as the round-head screws of the outer panels.
  • Afterwards, the U-shaped cover can be carefully removed by pulling it straight upwards.
Step 3

Identifying the defective gear

  • Determine when the gears bind by turning them slightly. If a gear on the transfer axis is affected, it should only move about 1 cm back and forth. Turn carefully, as excessive force can bend the delicate mechanism. If necessary, remove the elevator first.
Step 4

Removing the elevator

  • A TX1.5 and a TX10 screwdriver are required here.
  • Remove the 4 small countersunk screws at the top.
  • Remove the two rear round-head screws.
  • Carefully pull the metal bracket upwards. Caution: since the ribbon cable is glued to the metal bracket, the cable will be pulled out of the connector on the lower PCB.
  • Carefully open the ribbon cable connector on the elevator PCB and pull the cable out.
  • Then carefully turn the gears on the left and right towards the back to slowly move the elevator upwards. Try to overcome any blockages as you do so.
  • If it is absolutely impossible because the defective gear is completely blocked, you can remove one of the two gear rack towers. However, since there is also a TX1.5 mounting screw on the inside of each, you must at least move the elevator up far enough to reach them.
Step 5

Replace the outer gear

  • If the outer gear is defective, simply slide it off using a lever. Since the gear is broken, this should be quite easy.
  • The gears on the left and right must be aligned so that they mesh perfectly. For example, align one tooth vertically pointing upwards on each.
  • Then, carefully slide on a new gear with 12 teeth and an axle hole diameter of x, ensuring the aligned teeth do not shift, otherwise the elevator will operate unevenly. Therefore, work as precisely as possible here.
Step 6

Inner gear replacement

  • If the inner gear on the drive side is defective, the bearing plate and the drive reduction gear must first be pulled off:
  • Remove the four TX1.5 screws for the gear set counter-bearings and carefully pry off the plate. This should be quite easy to do.
  • Remove the transmission gear between the motor and the transmission.
  • Then, pry off the transfer axle gear, which should again be quite easy to do if it is broken.
  • Check again whether the transmission assembly can now rotate freely (otherwise another gear is affected).
  • The gears on the left and right must then be aligned so that they fit together perfectly. For example, align one tooth vertically upwards on each.
  • Then carefully slide on a new one with 12 teeth and a hole diameter of x for the axle, without changing the aligned teeth, as otherwise the elevator will move unevenly. Therefore, work as precisely as possible here.
Step 7

Reinstalling the elevator

  • Check that the rack gears are running synchronously and without any obstructions.
  • Place the elevator on the rack towers and lower it slightly again.
  • Attach the ribbon cable to the elevator.
  • Connect the ribbon cable to the transport unit board.
  • Reinstall the metal bracket and screw it into place.
  • Reattach the transport unit.