Step 1

End Stops

  • Make sure none of the end stops are triggered.
  • Manually trigger the X end stop and re enter M119. It should return a status of "at min stop" for X and Y should say "not stopped"
  • Manually trigger the Y end stop and re enter M119. It should return a status of "at max stop" for Y and X should say "not stopped"
Step 2

BLTouch

  • You should have a Macros folder for your BLTouch. Select Deploy, the pin should deploy. Select Retract, the pin should retract.
  • If the BLTouch starts blinking at any point normally it's a bad connection check your wiring.
  • Occasionally running the "Alarm Release Pin Up" macro can solve a blinking BLTouch
Step 3

Calibrate Z Offset

  • Heat the nozzle to 200c and bed to 60c and wait for the temperatures to stabilize. Remove any filament that is stuck to the nozzle.
  • If you have independent axis leveling configured make sure you run. Home all axis.
  • Jog the nozzle to the center of the bed. If using my github config, move the hotend X-40 so the nozzle is in the center of the bed.
  • Place a piece of paper under the nozzle.
  • A lot of times when calibrating Z offset the bed can't move up high enough because we don't have it configured to allow Z to go past 0. Out of habit when calibrating Z offset I will send G92 Z15 which tells the printer the new Z position is Z15. This will give me more than enough to calibrate the Z offset now.
  • In the console enter
  • M558 P9 C"^zprobe.in"
  • G31 P500 Z1.0
Step 4

Calibrate Z Offset

  • Jog the bed up carefully using the Z-.50 and Z-.05 buttons until the nozzle grips the paper
  • Once the nozzle grips the paper send G92 Z0
  • Lower the bed 10mm
  • Move the probe to bed center(same amount as step 3 but move it to the right)
  • Send G30 S-1. This will probe the bed and tell you the offset. Move the bed to Z10 and run G30 S-1 again. Repeat this step a couple of times. When finished move the bed to Z10.
  • Take the average of the Z offset readings from the console and replace your current G31 P500 X-42.45 Y0 Z## in config.g
  • Save and restart your printer