Breville Duo-Temp 800ESXL Gasket Replacement

If you’ve rescued a Breville Duo-Temp 800ESXL...

iFixit Library Breville Moderate 15 - 20 minutes Guide 145305
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

If you’ve rescued a Breville Duo-Temp 800ESXL espresso machine from the dumpster or simply haven’t used yours in a while, chances are the group head gasket needs replacing. The gasket creates the seal between the portafilter (which contains the coffee) and the group head of the espresso machine, ensuring water is pressurized through the grounds for good extraction. A cracked gasket will allow for pressure and water leaks resulting in poor espresso. Before beginning, make sure your espresso machine is unplugged and completely cool.

Step 1

Repair step

  • With your left hand, strongly grip the handle of the portafilter.
  • Pull the handle to your left. This will unlock the portafilter.
  • If the portafilter lock is too tight, place your hand on the top or bottom of the machine to provide additional leverage.
  • Gently push down to release the portafilter.
Step 2

Repair step

  • Slide the drip tray towards you to remove and set aside.
  • Two holes in the middle of the tray are available to make the tray easier to hold on to when removing.
  • Grasp the water reservoir using the front indention and the bottom of the tank.
  • Pull the water reservoir towards you to remove and set aside.
  • The drip tray and the water reservoir may contain water. Avoid spills if possible.
Step 3

Repair step

  • Carefully lay the espresso machine on its side.
  • The espresso machine is top heavy with the drip tray and the water reservoir removed.
Step 4

Repair step

  • Line the Phillips screwdriver up with the screw located in the center of the group head screen.
  • Turn the screwdriver counter clockwise to remove the 6 mm Phillips #1 screw.
  • If the screw is tight, use both hands to turn the screw driver.
  • Applying pressure to the screwdriver will help prevent stripping the screw.
Step 5

Repair step

  • Insert the opening tool between the housing and the gasket.
  • Pry the gasket loose from the housing.
  • The screen is contained within the gasket and will not be damaged by prying the gasket loose.
Step 6

Repair step

  • Remove the gasket and screen from the machine.
  • Peel back the gasket from the screen in a circular motion.
  • If the gasket is firmly stuck to the screen, soak in warm soapy water for approximately 30 minutes to loosen the coffee buildup.
  • Discard the old gasket.
Step 7

Repair step

  • Soak the group head screen in warm soapy water.
  • Clean the group head with a nylon espresso machine brush and warm soapy water.
  • Scrub the group head screen with a nylon espresso machine brush.
  • The group head screen should be completely free of coffee oils and build up.
Step 8

Repair step

  • Place the group head screen inside the new gasket.
  • Firmly press the screen into the seal in a circular motion.
  • The screen fits snuggly but easily within the gasket.
Step 9

Repair step

  • Place the gasket and screen back into the espresso machine.
  • Insert the 6 mm Phillips #1 screw back into the middle of the screen and tighten in a clockwise direction.
  • The tightness of the screw should be firm but not difficult to loosen. Do not over tighten the screw.
Step 10

Repair step

  • Set the espresso machine upright.
  • Reattach the water reservoir and drip tray.