Before you begin

These instructions may also help with other Nivona models and with coffee makers from Melitta, Siemens, and Miele—they are all made by the same manufacturer and have a very similar design. If water drips from the stationary machine, the water connection seal ("inner manifold sleeve") may be defective. Note: In the instructions it is shown that the upper part and both side parts are removed. If no repairs other than the water connection seal are necessary, the upper part and the side part with the service door do not need to be removed, then skip steps 4 to 6.

Step 1

Repair step

  • Pull the power plug!
  • Remove all attachments such as water reservoir, coffee compartment lid, trestle drawer. Remove all coffee beans in the storage container.
  • Unscrew the five Torx T10 screws on the back.
Step 2

Repair step

  • Unscrew the two Torx T10 screws on the front edge of the heat plate.
  • Do not remove the heat plate completely yet, its supply cables are still connected.
  • Lift the front edge of the heat plate and slide it forward a bit to clear the tabs on the back edge.
  • Put the heat plate back down, but in such a way that you can reach the screws underneath.
  • Unscrew the two Torx T10 screws located under the heat plate.
Step 3

Repair step

  • Gently lift the upper side a bit and put it back down.
  • Push the side panel on the water tank back about 2 cm.
  • This may jam a bit.
  • Place the side panel next to the machine. Do not remove it completely yet, the cables of the switch are still connected.
  • Disconnect the flat plugs from the switch. Be sure to note the order of the cables for later reassembly.
  • Remove the side panel.
Step 4

Repair step

  • Loosen the two insulated flat plugs with which the heat plate is connected.
  • Lift the top slightly upwards and loosen the nut that secures the eyelet to the green-yellow grounding cable. Remove the eyelet.
  • Do not remove the top yet, it is still connected with a sensor cable.
Step 5

Repair step

  • Lift the top side slightly.
  • Press down the locking tab on the plug of the white sensor cable and pull off the black plug towards the front of the machine.
  • Press the two catches of the counterpart on the sides together and slide it out of the opening towards the back.
  • Now the top is free and you can remove it.
Step 6

Repair step

  • Slide the side panel with the service door back about 2 cm and remove it.
  • This may jam a little.
Step 7

Repair step

  • The water connection seal is covered with a plastic cap. This cap is fixed with two Torx T10 screws. Unscrew both screws.
  • Lift out the cap with your fingers.
  • Lift out the water connection seal with your fingers.
  • Grease the seal thinly with food-grade silicone grease before installation. The gasket must be inserted with the flat side facing up.