Guide overview

Before you begin

This guide will show you how to replace the trigger in a Dyson V11 Torque Drive vacuum cleaner. Since the trigger is made of plastic is it easily breakable. If the trigger on your Dyson V11 Torque Drive is broken then it will not start vacuuming. Even if the battery is fully charged, the Dyson V11 Torque Drive will not start vacuuming. Once you replace the trigger the Dyson V11 Torque Drive vacuum should be operational agin and it will start vacuuming. Tools you will need to replace the trigger on the Dyson V11 Torque Drive vacuum are a Phillips #1 screw driver, Phillips #0 screw driver, and a spudger.

Step 1

Remove handle screw

  • Remove one Phillips #1 screw from the back of the handle
Step 2

Remove battery screws

  • Remove the two Phillips #1 screws from the underside of the battery.
Step 3

Remove the battery

  • Pull down on the battery to slide it out of the handle.
Step 4

Remove the filter

  • Twist the filter and then slide it off to remove it.
Step 5

Unscrew the handle

  • Remove the four screws beside the battery indicator with a Phillips #1 screwdriver.
Step 6

Repair step

  • Remove two screws next to the handle using a Phillips #1 screwdriver.
Step 7

Repair step

  • Separate the handle and the front end of the vacuum cleaner.
Step 8

Repair step

  • Remove two screws from the protective case covering the circuit board.
  • On some models these screws are Phillips #0, on others Torx #8.
Step 9

Remove the circuit board casing

  • The circuit board casing is very stiff and can be difficult to remove. The key is to use a spudger to pry near the rectangular protrusions, as these cover the plastic clips.
  • It can also help to slide a jimmy under the casing where you just removed the screws from, and pry from there to loosen that side.
Step 10

Remove glue covering

  • The circuit board may be covered with a great deal of translucent glue. We need to access three things under this covering: two power connections, and the switch cable.
  • Carefully scrape or cut the glue away from the screw heads and power cables.
  • In the same way, free the switch cable and its plug.
  • If using a sharp tool, be careful not to damage any wiring during this step.
Step 11

Disconnect the power cables

  • Remove the screws holding down the power cables.
  • On some models these are Phillips #1 screws, on others Torx #8.
Step 12

Disconnect the switch cable

  • Gently disconnect the switch cable plug and lift the cable up from the circuit board so that it doesn't tangle with the black and white wires.
Step 13

Repair step

  • Rotate the ends of the power cables so that they fit through the slot in the lower circuit board casing more easily.
  • Remove the center part from the outer shell. Ideally, gently push the cables out through the slot, but this may be difficult — you may need to use some force to pull the center part away.
Step 14

Repair step

  • Remove the single screw inside the charging compartment with a Phillips #0 or Torx screwdriver, depending on the screw installed in your model.
Step 15

Remove the cable casing

  • Remove two screws from the cable casing.
  • These may be Phillips #0 or Torx screws, depending on the model.
  • Pry the cable casing up to free the clips. You may need to push on the clips with a screwdriver or tweezers.
  • Slide the casing off the cables.
Step 16

Remove the switch mechanism

  • Use a spudger to push the part marked in the image to remove the trigger from the charging compartment.
  • This requires a reasonable amount of force.