iTeufel Air defective | Standby LED does not light up

A common error with the iTeufel Air is the...

iFixit Library ITeufel Air Very difficult No estimate Guide 148611
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

A common error with the iTeufel Air is the defect of the 5V power pack for the power supply of the main board. This can be recognized by the fact that the iTeufel Air's standby LED no longer lights up. Normally, when the iTeufel Air is plugged in, the standby LED should light up orange. The cause of the defect in the 5V power supply is a defective diode (P6KE 200A) on the circuit board, which leads to failure of the power supply. Note: These instructions are intended for specialists with electrical engineering experience. If you are not a specialist, a repair in a repair cafe or similar is recommended! The repair involves working on the main board, which has potentially lethal voltages of 230 V!

Step 1

opening the case

  • Open the iTeufel Air by prying open the speaker cover on both sides with a pry tool so that the cover detaches from the rest. It is recommended to use the plastic lifter at the points marked in red and carefully lift the cover 2-3 cm so that the adhesive strips detach from the cover.
  • If the cover doesn't come off with a plastic pry bar, you can gently try it with a small flathead screwdriver
  • If you have loosened the cover on one side, fix the cover so that it remains open, e.g. with the plastic lifter and loosen the cover on the other side as well.
  • Before you start, unplug the iTeufel Air from the socket!
Step 2

Repair step

  • Now open the front cover by lifting it up with the plastic lifter between the black cover and the white frame. The cover is glued to the housing at the 4 points marked in red.
Step 3

Repair step

  • Now unscrew the loudspeakers from the housing with a PH 2 screwdriver.
  • Then lever the cover with the speakers off the housing by lifting the black cover slightly at the points marked with the arrows using a plastic lifter.
Step 4

Repair step

  • Now carefully lift off the plate with the loudspeakers and place them in front of the housing.
  • Be careful not to tear off the cables. The cables to the loudspeakers may have to be brought out from under the bass reflex tubes.
Step 5

Repair step

  • Now the bass reflex tubes have to be removed from the housing. These are glued all around the white housing. The adhesions can be carefully cut off with a knife.
  • The best way to push the bass reflex tube out of the white housing is from the inside to the outside.
Step 6

Unscrew the power pack

  • Now unscrew the circuit board of the power supply with a PH 2 screwdriver.
  • Before you remove the circuit board, disconnect the circuit board connector for the power supply (black cable) and the white circuit board connector to the main circuit board.
Step 7

Power supply repair

  • The defective diode is marked with the red circle. Replace this with a soldering iron for an identical diode (P6KE 200A) and pay attention to the polarity of the new diode when installing
  • A defective diode is not always visually recognizable. If so, the diode should be unsoldered and checked using the diode test mode of a multimeter.
Step 8

Another cause of error

  • If the diode is functional, other components of the 5V power supply may also be defective.
  • In the event of overvoltage damage (e.g. lightning strike), the following components can be defective: fuse (5mm grid), IC switching power supply (TNY 280 PN) and the bridge rectifier (on the back of the circuit board). These all need to be replaced.