FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Apple Watch Series 7 Screen Replacement

Use this guide to replace a broken, cracked, or...

iFixit Library Apple Watch Series 7 Moderate 30 - 50 minutes Guide 152656
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Use this guide to replace a broken, cracked, or defective screen on your Apple Watch Series 7. It is possible to replace the screen of the Apple Watch Series 7 without removing or disconnecting the battery first. However, this can lead to a malfunction of the NFC antenna under certain circumstances. If you are unsure about your repair, we recommend that you first follow the battery guide and then continue with Step 23 of this guide. Replacing the display can cause issues with Apple Pay. If possible, to reduce the likelihood of problems, delete all your Apple Pay account info before the replacement, and then re-enter it with the new display installed. This guide shows the procedure on the cellular/LTE version of the watch, but the standard GPS-only version is similar. You’ll need replacement adhesive to reattach components when reassembling the device.

Step 1

Power down the watch

  • Before starting repairs, take your watch off the charger and power it down.
  • If your touchscreen is broken and you can't power off the watch, use this alternate method to power it down.
Step 2

Safety Requirements

  • Because the gap between the screen and watch body is so thin, an iFlex is needed to separate the two.
  • Protect your fingers by keeping them completely clear of the iFlex edge. If in doubt, protect your free hand with a heavy glove, such as a leather shop glove or gardening glove.
  • Be careful not to apply too much pressure, as this might cause the iFlex to slip and cut you, or damage the watch.
  • Wear eye protection. If the opening procedure is performed incorrectly or with too much pressure, the glass could crack, sending small glass shards flying.
  • Attach or remove the watch band as needed to provide more control as you make repairs.
Step 3

Soften the display adhesive

  • Prepare an iOpener and apply it to the screen for at least two minutes to loosen the adhesive underneath.
  • A hair dryer, heat gun, or hot plate may also be used, but be careful not to overheat the watch—the display and internal battery are both susceptible to heat damage.
  • You may need to reheat the iOpener and repeat this procedure several times until the display adhesive softens.
Step 4

Create a gap

  • Don't grip the iFlex or similar metal tools by the edges—they're very sharp. Consider wearing gloves to protect your hands.
  • Insert the iFlex at a downward angle between the bottom edge of the screen and frame.
  • The Apple Watch Series 7 display is equipped with a plastic bezel on its rear side. If you want to reuse your display, avoid using too much pressure with the iFlex or you may separate the bezel from the screen.
Step 5

Pry up the screen

  • Prying up the screen may take multiple attempts. If you're having trouble, apply more heat and try again.
  • With one hand, push down firmly on the watch's frame to secure it in place.
  • With your free hand, hold the iFlex and push the edges up to make it more rigid.
  • The iFlex should be slightly "U" shaped.
  • Pry up the screen enough for the iFlex to lay flat on its own.
  • The iFlex doesn't need to be inserted far, as it can easily damage the screen cables near the bottom right corner of the watch.
  • Leave the iFlex inserted under the screen.
Step 6

Insert an opening pick

  • Do not insert your opening pick more than 3 mm under the screen when separating the adhesive, as you risk damaging your watches internals.
  • Keep the iFlex flat to maintain a gap between the screen and frame while inserting an opening pick.
  • Insert an opening pick between the screen and iFlex.
  • Remove the iFlex.
Step 7

Slice the adhesive

  • Slide the opening pick around the bottom left corner and up the left edge.
Step 8

Repair step

  • Slide the opening pick around the corner and along the long edge on the opposite side of the watch crown to slice the display adhesive.
Step 9

Repair step

  • Slide the opening pick around the corner to slice the remaining adhesive on the short edge of the watch next to the watch crown.
  • Don't try to remove the display. It is still connected to the watch assembly.
Step 10

Swing open the display

  • Be careful not to strain the display cables when you fold the display to the side.
  • Lift the display and carefully pull it towards the watch crown.
  • Swing the display open to an upward position.
Step 11

Soften the battery adhesive

  • Prepare an iOpener and apply it to the rear side of your Apple Watch for at least two minutes to loosen the adhesive underneath the battery.
  • A hair dryer, heat gun, or hot plate may also be used, but be careful not to overheat the watch—the display and internal battery are both susceptible to heat damage.
Step 12

Determine which procedure to follow

  • From this point, the battery removal procedure for the 41 mm watch differs slightly from the 45 mm version.
  • If you're replacing the battery for a 41 mm watch, continue with this step.
  • If you're replacing the battery for a 45 mm watch, continue with this step.
Step 13

Pry up the battery

  • The following six steps show how to remove the battery from a 41 mm Apple Watch Series 7.
  • Insert an opening pick between watch body and the long edge of the battery.
  • Use constant, steady pressure to slowly pry up the battery.
  • Take care not to puncture or bend the battery with your tool—a punctured or bent battery may leak dangerous chemicals or cause a fire.
  • Don't try to remove the battery all the way yet. It is still connected to the motherboard.
Step 14

Move the battery

  • The battery flex cable is long enough to allow you to place the battery outside the watch housing, but avoid straining or folding the the cable sharply when you lift the battery out of its recess.
  • Carefully lift and swing the battery out of its recess and place it next to the watch body.
Step 15

Peel the black protective tape off the ZIF connector

  • Use a pair of tweezers to peel the black protective tape off the ZIF connector.
  • Make sure to only peel the tape off the connector but avoid to remove it completely. Otherwise you have to replace the tape during reassembly.
Step 16

Open the ZIF connector

  • Use one arm of your tweezers or the pointed end of a spudger to pry up the lock bar on the ZIF connector securing the battery cable.
Step 17

Disconnect the battery

  • Use a pair of tweezers to pull the battery cable out of the battery ZIF connector.
  • During reassembly make sure to push the cable all the way back into the ZIF connector before locking the it. Reapply the black tape on top of the connector to secure the battery cable or replace it with new one. Otherwise the battery cable may slip out of the connector and your watch won't turn on.
Step 18

Remove the battery

  • Remove the battery.
  • Do not reuse the battery if it has been deformed or damaged, as doing so is a potential safety hazard. Replace it with a new battery.
  • If you're reusing your old battery during reassembly, you can reuse the existing adhesive to secure the battery during reassembly.
  • Secure a new battery with pre-cut adhesive or double-sided adhesive tape. In order to position it correctly, apply the new adhesive into the device at the places where the old adhesive was located, not directly onto the battery. Press the new battery firmly into place.
Step 19

Pry up the battery

  • The following six steps show how to remove the battery from a 45 mm Apple Watch Series 7.
  • Insert an opening pick between watch body and the long edge of the battery.
  • Use constant, steady pressure to slowly pry up the battery.
  • Take care not to puncture or bend the battery with your tool—a punctured or bent battery may leak dangerous chemicals or cause a fire.
  • Don't try to remove the battery all the way yet. It is still connected to the motherboard.
Step 20

Move the battery

  • The battery flex cable is long enough to allow you to place the battery outside the watch housing, but avoid straining or folding the the cable sharply when you lift the battery out of its recess.
  • Carefully lift and swing the battery out of its recess and place it next to the watch body.
Step 21

Unfasten the battery connector bracket screw

  • Use a Tri-Point Y000 screwdriver to remove the 1.1 mm-long screw securing the battery connector bracket.
Step 22

Remove the battery connector bracket

  • Use a pair of tweezers to remove the battery connector bracket.
Step 23

Disconnect the battery cable

  • Use a spudger to disconnect the battery cable by prying the connector straight up from its socket.
Step 24

Remove the battery

  • Remove the battery.
  • Do not reuse the battery if it has been deformed or damaged, as doing so is a potential safety hazard. Replace it with a new battery.
  • If you're reusing your old battery, you can reuse the existing adhesive to secure the battery during reassembly.
  • Secure a new battery with pre-cut adhesive or double-sided adhesive tape. In order to position it correctly, apply the new adhesive into the device at the places where the old adhesive was located, not directly onto the battery. Press the new battery firmly into place.
  • During reassembly apply new adhesive where necessary after cleaning the relevant areas with isopropyl alcohol (>90%).
Step 25

Peel the protective tape off the display connectors

  • Use a pair of tweezers to carefully peel the black protective tape off both display connectors.
  • During reassembly, this is a good point to power on your watch and test all functions before sealing it up. Be sure to power your watch back down completely before you continue working.
Step 26

Open the ZIF connectors

  • Use a spudger or one arm of your tweezers to pry up the lock bar on the ZIF connectors securing the display cables.
Step 27

Soften the protective tape adhesive

  • Prepare an iOpener and apply it to the screen for at least two minutes to loosen the protective tape on its rear side.
  • A hair dryer, heat gun, or hot plate may also be used, but be careful not to overheat the phone—the display and internal battery are both susceptible to heat damage.
Step 28

Separate the display cables

  • Carefully slide an opening pick underneath the display cables to separate them from the screen.
Step 29

Disconnect the display cables

  • Use a pair of tweezers to pull both display cables out of the ZIF connectors.
  • Avoid pulling on the watch assembly, or you may rip the display cables.
  • If not damaged you can reuse the old tape during reassembly. Otherwise replace it with new tape.
Step 30

Remove the screen

  • Remove the screen.
  • Apply new adhesive where it's necessary after cleaning the relevant areas with isopropyl alcohol (>90%).