Titan Airless Sprayer IMPACT 410 Pressure Adjustment Assembly Replacement

Use this guide to replace the pressure...

iFixit Library Titan Airless Sprayer IMPACT 410 Moderate 30 - 45 minutes Guide 153216
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Use this guide to replace the pressure adjustment assembly in your Titan Impact 410 Airless Sprayer.

Step 1

Safety precautions

  • Before you begin, make sure to follow the pressure relief procedure documented in the user manual before powering down the paint sprayer and disconnecting the pump.
  • Turn off and unplug the sprayer.
Step 2

Unfasten the motor controller assembly

  • Use a Phillips driver to remove the four 12 mm-long screws securing the motor controller assembly.
Step 3

Reposition the motor controller assembly

  • Don't try to remove the motor controller assembly completely, as it's connected to the body with cables.
  • Pull the motor controller assembly out and hold it to the side, exposing the cables.
Step 4

Disconnect the spade connectors

  • Use a pair of needle nose pliers, or your fingers, to disconnect the two spade connectors from to the on/off switch.
  • Disconnect the one spade connector on the circuit breaker.
  • Note the order of the cables and their connectors to help with reassembly.
Step 5

Repair step

  • Disconnect the remaining spade connector from the on/off switch
  • Disconnect the jumper spade connector from the on/off switch and the circuit breaker.
  • The black jumper cable with the dark blue connectors isn't attached to the rest of the assembly.
  • Note the order of the cables and their connectors to help with reassembly.
Step 6

Remove the circuit breaker

  • Use your fingers to unscrew and remove the circuit breaker nut.
  • Remove the circuit breaker.
Step 7

Remove the on/off switch

  • Use a flathead screwdriver to depress the locking tabs located on both the top and bottom of the on/off switch.
  • While depressing the tabs, push the on/off switch out through the cutout.
  • Remove the on/off switch.
Step 8

Unfasten the contact switch

  • Use a Phillips driver to remove the two 17 mm-long screws securing the contact switch.
Step 9

Reposition the contact switch

  • Pull the contact switch away from the plunger and place it on the floor of the housing.
Step 10

Remove the retaining ring

  • Use snap ring pliers to remove the retaining ring from the top of the plunger.
  • During reassembly, install a new ring with the flat side facing down.
Step 11

Remove the control knob

  • Loosen the pressure control knob.
  • Remove the pressure control knob.
Step 12

Remove the pressure adjustment spring

  • Remove the pressure adjustment spring.
Step 13

Remove the plunger

  • Remove the plunger.