LED-bulb 230V E27 repair

in 230V LED bulbs are many individual LEDs conn...

iFixit Library LED Birne 230V Moderate 30 minutes Guide 154492
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

in 230V LED bulbs are many individual LEDs connected in series, like in an old Christmas tree light chain, and if one of them fails, then the lamp remains dark, or flickers ...., and the normal consumer can only dispose of it ..... but unlike incandescent bulbs and energy-saving lamps, LED bulbs can be repaired .... not always, but often ....

Step 1

Open the bulb

  • the luminous hemisphere is made of plastic and glued to the lower part
  • slight mechanical deformation loosens the bond and the hemisphere comes off .. sometimes it's easy, sometimes it's tough .. A matter of luck
Step 2

Repair possible?

  • now you can see the inner workings: many small LEDs, connected in series, and a plug or solder connection leading downwards
  • unfortunately it is almost impossible to replace a defective LED, because of the heat dissipation, but you can easily bridge a defective LED
  • and again you can be lucky or unlucky, depending on the manufacturer and year of construction
  • If there are other components in addition to the LEDs (Image 1): Bad luck, lamp has no voltage converter, is not repairable
  • if there are less than 10 LEDs (Image 2): also unlucky, not repairable. The voltage transformer can not compensate for a missing LED
Step 3

Identify defective LED

  • sometimes you can see the burned out LED with the naked eye, by a black spot; then you can skip the following steps:
  • You need two pointed test probes, either directly connected, or with a multimeter in the mA range.
  • put the lamp under current, attention, mains voltage, from now on fingers away !
  • bridge a LED with the test probes, one after the other, if it suddenly lights up, you have found the bad LED
  • note position, turn off the power!
  • (of course it can also be the voltage transformer defective, but that is unlikely. In my experience, to test the transformer is difficult, because without a suitable load it does not run)
Step 4

Bridge the defective LED

  • with a small piece of thin wire, or a blob of solder
Step 5

Hooray, lamp shines again !

  • (with slightly reduced power)