Guide overview

Before you begin

There is a manual for this oscilloscope: TBS1000 Series Service Manual Complete disassembly is best achieved by following the procedures in the order given in the following table: 1) Rear Feet (See page 6-8, Rear Feet.) 2) Flip Feet (See page 6-9, Flip Feet.) 3) Front-Panel Knobs (See page 6-9, Front-Panel Knobs.) 4) Rear Case (See page 6-10, Rear Case.) 5) Front Feet (See page 6-11, Front Feet.) 6) Power Supply Module (See page 6-12, Power Supply Module.) 7) Internal Assembly (See page 6-13, Internal Assembly.) 8) Front-Panel Cable (See page 6-15, Front-Panel Cable.) 9) Main Board Module (See page 6-16, Main Board Module (without the Display Adapter Module.) 10) Display Module (See page 6-19, Display Module.) 11) Front-Panel Module (See page 6-20, Front-Panel Module.) 12) Keypad|(See page 6-21, Keypad.)

Step 1

Removing the front panel

  • Remove all eight plastic buttons.
  • Remove the five Torx T15 screws.
  • Remove the front panel by pulling it off
Step 2

Removing the back cover

  • Remove the power plug from the cover
  • Firmly grasp the ON/OFF switch and pull it straight out of the box.
  • Press the button into the ON/OFF button recess until it clicks into place.
  • Remove the two black plastic plugs from the bottom.
  • Remove the five Torx T15 screws.
  • Remove the back cover.
Step 3

Power supply removal - ATTENTION

  • Even when disconnected, the power supply can retain a dangerously high voltage. Avoid contact with the rear of the board or other components. Use insulated electrician's gloves. Ensure that the capacitors are discharged before touching them.
  • Disconnect the J101 power supply connector from the motherboard.
  • Disconnect the earth connection.
  • Remove the 5x Torx T15 screws.
  • Remove the power supply board.
Step 4

Control panel removal

  • Disconnect the black cable from the motherboard
  • Remove the 5x Torx T15 screws
  • Pull the control board plate
Step 5

Removing the mainboard

  • Loosen the three nuts holding the signal connectors.
  • Loosen the three T15 Torx screws.
  • Remove the cables.
  • Remove the main board.
Step 6

LCD display removal

  • Disconnect the ribbon cable and the LCD backlight cable from the motherboard.
  • Loosen the 4x 8mm nuts from the display supports.
  • Remove the LCD display.