Official iFixit API visual reference

Replacement thermal fuse on bread machine

Description of the disassembly and diagnostic...

iFixit Library Moulinex Home Bread Moderate 45 minutes Guide 155414
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Description of the disassembly and diagnostic steps on Moulinex Homebread bread machine model 573801, ref: OW200030/B72 - 4308R where we come to the conclusion that a thermal fuse is to be replaced. Replacement of this fuse and reassembly. Two crimping rings are used to connect the fuse with its power cords. These two rings are also to be replaced. You have to choose them with a maximum inner diameter of 3 mm, otherwise we can have difficulty putting on the thermal protection braid after crimping. Work off power.

Step 1

Removing the lid

  • Place the cover in an upright position
  • Lift it out of its joint
Step 2

Removal of shutters

  • Remove the 4 shutters from the control panel with a very thin screwdriver. This can be difficult or even impossible.
  • Use a forest as a last resort to start a drill.
  • Catch each shutter with the forest
Step 3

Removing the control panel

  • With a PH2 screwdriver remove the 4 screws dia 3 x 13
  • Lift and tilt the panel forward
Step 4

Removal of the thermal crankcase

  • With a PH2 screwdriver remove the 4 upper screws dia 4.2 x 9.5
  • With a PH2 screwdriver remove the 4 lower screws M 4 x 6
  • Lift the crankcase
Step 5

Removal of the thermal screen

  • With a PH2 screwdriver remove the 2 screws dia 4.5 x 9.3
  • Tilt and slide the screen down along the two wires of the temperature probe
  • This gives you access to the environment of the two thermal fuses
Step 6

Removal of the thermal fuse holding flange

  • The purpose is to deposit the sheet metal flange that holds the two fuses (two large white and red textile sheaths) and the probe (small white sheath)
  • The maintenance of this flange is ensured by a single sheet metal screw whose head is accessible inside the thermal housing.
  • Use a small ratchet wrench or a short screwdriver with PH2 bit, and continue by hand.
Step 7

Diagnosis

  • The absence of a power supply requires a diagnosis. The electrical test can be facilitated by opening the back of the splices with a cutting clamp.
  • Open only the strict minimum to be able to pass the touch point of the multimeter.
  • Open only the strict minimum to be able to pass the touch point of the multimeter.
  • In our case, using the continuity function of the multimeter, it is the thermal fuse protected by the white sheath that is found to fail.
Step 8

Replacement of the fuse

  • Slide the textile sheath to make the fuse and its set rings appear.
  • Cut the wire at the level of the two rings
  • Bare on a length corresponding to those of new rings
  • Set up the three elements and crimp firmly.
  • Check the electrical continuity
  • Replace the textile sheath.