FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Bezzera Duo coffee maker Pressure regulator on rotary pump Replacement

The pressure regulator on my portafilter with...

iFixit Library Bezzera Duo Siebträgermaschine Difficult 2 hours Guide 156889
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

The pressure regulator on my portafilter with rotary pump no longer worked or could not be adjusted. In these instructions, I show which steps are necessary to replace the regulator. As a bonus, the removal of the pump head is described. Attention! This repair is not easy, as many things need to be approached with care. It is best to do this repair with a helper and to follow the warnings detailed in the first step.

Step 1

Repair step

  • Electric discharge warning: before starting the repair make sure to disconnect the machine from the mains or you might risk being electrocuted.
  • Heat warning: before starting the repair let the machine cool down at least 1h after last use or you might risk burns while repairing.
  • Injury warning: Sheet metal plates on the inside of the machine are not deburred and may cause serious cuts!
  • Last warning: The machine is very heavy and it is best to do this repair with a helping pair of hands. Secure the machine against falling when tilting it to a different position.
Step 2

Repair step

  • Remove the cup tray, water tank and water drain.
Step 3

Repair step

  • Remove 4 screws from the cover plate with a 3 mm Allen key and remove the plate.
Step 4

Repair step

  • Put a towel underneath and place the machine on the front and the brewing unit.
Step 5

Repair step

  • Disconnect the connector as shown.
Step 6

Repair step

  • Disconnect this connector too.
Step 7

Repair step

  • Remove the 8 hexagon socket screws that fix the housing at the bottom. Only 7 are visible in the picture.
Step 8

Repair step

  • Loosen two hex screws on the right and left of the casing plate with a 3 mm ball head hexagon socket; do not unscrew them completely.
  • Then remove the 8 screws of the housing plate on the underside of the machine (by the feet).
  • Push the housing plate a little towards the feet and swing it out upwards/backwards
Step 9

Repair step

  • Unscrew the condenser from the tank retaining plate using a 13 mm spanner.
Step 10

Repair step

  • Remove the ring nut that fixes the tank connection in the tank guide plate. To do this, move the 22mm spanner a little and hold the ring nut against it with a screwdriver. The ring nut itself is extremely tight and cannot be turned with the wrench.
Step 11

Repair step

  • Remove two hex screws holding the tank guide plate in place.
Step 12

Repair step

  • Additional information: For a complete exchange of the pump head, the three screws and nuts marked in green would have to be loosened. Here, however, we are talking about the pressure regulator (marked red in the second picture).
Step 13

Repair step

  • This can now be loosened with an open-ended spanner.
Step 14

Repair step

  • Removed pressure regulator: it was completely stuck due to corrosion and thus prevented much pressure from being released.
  • The counterpart to the regulator, which is still in the pump: It sits directly on the black stamp of the pressure regulator during operation. If it is stuck in the pump, this must also be replaced.
  • Note on the above-mentioned part in the yellow circle: the part is held in place by a coil spring, which is not shown in the picture. When replacing, make sure that this spring does not disappear into the pump housing!