Repair step
- 14.4V BATTERY TESTER FOR CONGA AND ROOMBA ROBOT CLEANERS; one of the common failures in robot cleaners is a dead battery that no longer holds a charge.
- Testing the battery with a multimeter on the DC voltage scale is simple, but BE CAREFUL: we are testing the battery at no-load, WITHOUT A CONNECTED LOAD, so the reading provided by the voltmeter will not be real. It will give a measurement higher than the voltage the battery actually has, which can completely skew the test, leading you to think it is OK.
- This idea came to me while testing a Conga robot battery at Repair Café Palma, seeing all the problems it presented and the time we were losing for a relatively simple test, so I decided to build a voltage tester with a 3-scale load application to see how the battery behaves.
- To be able to measure the real voltage of the battery, we apply a load in mA (milliamps) or Amps, but we cannot exceed the consumption either. This tester can apply 3 different consumption levels to perform an evaluation of the status, according to the load applied.