Guide overview

Before you begin

Use this guide to replace the vent valve plunger in your LG front load washing machine. The vent valve plunger vents moist air out the back of the washer. The plunger may stick open, which would allow excess liquid to slosh out and drip down the back of the washer. This guide will work for most LG front load washing machines. This guide is written with a model WM3050CW washer. If you have a different model, you may encounter some minor disassembly differences, but the overall repair process will be the same.

Step 1

Repair step

  • Before you begin your repair, perform the following:
  • Turn off the main water supply
  • Unplug your washer
  • Disconnect all water connections at the rear of your washer
Step 2

Unfasten the top panel

  • Remove the screw(s) securing the top panel brackets to the back panel.
  • You don't need to remove the screws securing the brackets to the top panel.
Step 3

Remove the top panel

  • Slide the top panel towards the rear of the device to disconnect its clips.
Step 4

Repair step

  • Tilt the top panel upward to completely disconnect it from the chassis.
  • Remove the top panel.
Step 5

Inlet valve information

  • To prevent confusion, label each valve and its corresponding hose.
  • You can use masking tape or mark the components themselves.
  • Repeat the labelling procedure for each valve and its corresponding connector.
Step 6

Disconnect the inlet valve

  • Disconnect the connectors from the inlet valve.
  • Always grip cables by their connectors and not the wires themselves.
Step 7

Repair step

  • Place a dry rag under the inlet valve to soak up any lingering water.
Step 8

Repair step

  • Use slip joint pliers to pinch the inlet valve hose clamp and pull it away from the inlet valve assembly.
Step 9

Repair step

  • Use slip joint pliers to rotate the inlet valve hose back and forth around its connection and loosen it.
Step 10

Repair step

  • Pull the inlet valve hose straight off its connection on the inlet valve assembly.
Step 11

Repair step

  • Repeat the previous three steps for each remaining hose attached to the inlet valve assembly.
Step 12

Remove the filters

  • If your replacement part comes with filters pre-installed, skip this step.
  • Use needle nose pliers to pull the inlet valve filters straight out of the inlets in the chassis.
  • Remove the filters.
Step 13

Unfasten the inlet valve assembly

  • Remove the screws securing the inlet valve assembly.
Step 14

Remove the inlet valve assembly

  • Pull the inlet valve assembly straight out of its slot in the chassis to remove it.
Step 15

Reposition the vent hose

  • Loosen the fastener securing the vent hose.
  • Lift the vent hose straight off the drum to expose the vent valve plunger.
Step 16

Remove the vent valve plunger

  • Use two flathead screwdrivers, or similar tools, to pry the vent valve plunger up enough to grip it with your fingers.
  • Pull the plunger straight up to remove it.