The blender would not turn on at all, or only sporadically, for example after a good shake or tap on the housing.

Step 1

Repair step

  • Pry off the gray cover over the cable feed. It is held in place by three latches, which are unlikely to survive the prying process intact.
  • One latch is located away from the power cable on the opposite edge of the bezel, and the other two are positioned about 120° apart. It is best to pry between two latches.
Step 2

Repair step

  • Underneath are three screws securing an intermediate cover, which also holds the cable grommet in place. Remove these, and you can then pull the cable grommet out of the device and slide it far enough along the power cord so that it no longer restricts the cable as you continue to open the device.
Step 3

Repair step

  • You can now see another screw located centrally deep inside the device. But before it is accessible to the screwdriver, you must remove the power button by carefully pressing its two side clips slightly inward.
Step 4

Repair step

  • Now, loosen the central screw deep inside to pull the two housing parts apart. This will reveal a small PCB with interference suppression elements, a fuse, and the power switch.
  • In our case, strong vibrations from the running motor had caused a supply line to break at the solder joint to the motor. After re-soldering and reassembly, everything worked again.