FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

iPad Pro 11" LiDAR Sensor Assembly Replacement

This is a prerequisite-only guide! This guide...

iFixit Library iPad Pro 11" Difficult No estimate Guide 159238
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This is a prerequisite-only guide! This guide is part of another procedure and is not meant to be used alone.

Step 1

LiDAR sensor assembly information

  • The LiDAR sensor assembly is paired to the Face ID hardware. You'll need to transfer it to your replacement screen to keep Face ID functionality. The following steps show how to remove the sensor assembly and install it on your replacement screen.
  • The LiDAR sensor assembly is composed of four total sensors:
  • Two ambient light sensors
  • One proximity sensor
  • One microphone
  • You'll need to separate each sensor from the screen before removing the entire assembly.
Step 2

Heat the top sensor assembly

  • Heat an iOpener and apply it to the top of the screen for two minutes.
Step 3

Separate the ambient light sensors

  • Insert one arm of your angled tweezers between the ambient light sensor and the screen.
  • You can also use a precision knife, but be careful not to damage the ribbon cable.
  • Pry up to separate the sensor from the screen.
  • This might take significant force.
  • Repeat this procedure for the other ambient light sensor.
Step 4

Separate the proximity sensor

  • Insert one arm of your angled tweezers between the proximity sensor cable and the screen.
  • Slide the tweezers toward the screen while prying to separate the sensor from the screen.
  • This might take significant force and multiple iOpener heating cycles.
Step 5

Peel away the tape

  • Peel off any tape covering the microphone.
  • Set the tape aside. You'll use it during reassembly.
Step 6

Separate the microphone

  • Slide an opening tool under the microphone to separate its adhesive.
  • Pry up to separate the microphone from the screen.
Step 7

Remove the LiDAR sensor assembly

  • Slide an opening pick under the LiDAR sensor assembly cable to separate it from the screen.
Step 8

Repair step

  • Continue sliding your opening pick under the LiDAR sensor assembly until it's completely separated from the screen.
  • Remove the LiDAR sensor assembly.
Step 9

Repair step

  • During reassembly, you'll have to perform the following:
  • Align the LiDAR sensor assembly on your replacement screen.
  • Use Tesa tape, or similar double-sided tape, to secure the cables to the screen.
  • Use E6000 adhesive, or similar adhesive, to secure the sensors to their cutouts on the screen.
  • Only apply adhesive to the edges of the sensors. Placing adhesive on the front will break them.