FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Pentax MZ-S Mirror Motor Gear Replacement

A common failure of the Pentax MZ-S camera is...

iFixit Library Pentax MZ-S Very difficult 2 - 4 hours Guide 160454
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

A common failure of the Pentax MZ-S camera is the Mirror Motor Gear. The gear drives core functions of the camera including the shutter and mirror movement. If it fails, the shutter will no longer fire and the mirror will be stuck close in the up position. This guide explains how to disassemble the camera to access the Mirror Motor Gear as well as how to install a new gear. A general understanding of how cameras work is recommended. Some technical soldering is also required.

Step 1

Remove film door

  • Push down the latch to release the film door.
Step 2

Remove top cover screws

  • Remove two 7.5 mm #00 screws.
  • Remove one 9.0 mm #00 screw.
  • Remove one 13.5 mm #00 screw from inside the battery compartment.
Step 3

Remove top cover screws

  • Push the button to pop up the flash.
  • Remove one 3.5 mm #00 screw.
  • Remove one 5.5 mm #00 screw.
Step 4

Lift top cover

  • Carefully lift the top cover away from the body to access wired connections.
  • The top cover is still connected in several locations.
Step 5

Access flash connections

  • Peel back the corner of the rubber grip.
  • Remove the small plastic cover.
  • Be careful not to short the wires before the flash capacitors have been properly discharged.
Step 6

Discharge flash capacitors

  • Use a 1kΩ-10kΩ high power resistor to discharge the capacitor. Place the resistor between the blue wire, exposed in the previous step, and ground.
  • The flash capacitors store energy at a very high voltage. Failing to discharge the capacitors properly could result in personal injury and/or damage to the camera.
Step 7

Disconnect right flex cable

  • Carefully lift the sides of the white latch.
  • Hold the flex PCB on the camera body in place as you lift to prevent damaging the flex.
Step 8

Disconnect left flex cable

  • Desolder the red wire.
  • Carefully lift the sides of the white latch.
  • Hold the flex PCB on the camera body in place as you lift to prevent damaging the flex.
Step 9

Desolder flash connections

  • Desolder blue, black, brown and green wires.
  • Remove the loose shim washer if present.
Step 10

Desolder the flash flex cable

  • Remove the piece of cellophane tape covering the flex connections.
  • Desolder flex connetions.
Step 11

Remove bottom cover

  • Use isopropyl alcohol to soften the adhesive under the country plate and remove.
  • Remove one 5mm #00 screw.
  • Remove one 7.5mm #00 screw.
  • Remove two 4.5mm #00 screws.
  • Remove one 5.5mm #00 screw.
  • Remove the plastic frame around the accessory grip contacts.
  • Reassembly Note: The camera can be checked for functionality at this point. Install the rear door, insert a fresh pair of batteries and try to fire the shutter.
Step 12

Remove front left cover

  • Remove one 4.0 mm #00 screw.
  • Remove left cover.
Step 13

Remove front cover

  • Remove front cover.
Step 14

Unscrew front right cover

  • Remove one 6.0 mm #00 screw.
  • Remove two 3.5 mm #00 screws.
  • Remove one 5.0 mm #00 screw.
  • Remove the strap lug.
Step 15

Remove the front right cover

  • Carefully pull the right panel away from the body. It is still attached.
  • Desolder the flex connections.
Step 16

Remove bottom plate

  • Remove the protective mask around the accessory grip contacts.
  • Lift the flex contacts free of their retaining posts. Use isopropyl alcohol to soften any glue or tape that is present.
  • Remove four 4.0 mm #00 screws (standard metric threads).
  • Remove four 4.0 mm #00 screws (plastic threads).
Step 17

Desolder speaker

  • Desolder the black and red wires for the speaker.
Step 18

Desolder connections to bottom flex circuit

  • Desolder the white and pink wires.
  • Desolder the red, black and gray wires.
  • Desolder the red, black and orange wires.
  • Desolder the white and blue wires.
  • Carefully peal the tape away and detach the red, black, white and blue wires from the glue. Use isopropyl alcohol to soften the glue if necessary.
  • Desolder the flex connection.
  • Desolder the flex connection.
Step 19

Desolder connections to top flex circuit

  • Desolder red, black, gray and orange wires.
  • Desolder flex contacts.
  • Disconnect flex connector.
  • Desolder yellow and purple wires.
Step 20

Desolder connections to top flex circuit

  • Desolder black wire.
  • Desolder battery contact tab.
  • Desolder flex contacts.
Step 21

Desolder flex connection above the lens mount

  • Desolder flex connection and remove from retention posts. Use isopropyl alcohol to soften the glue if necessary.
  • Carefully peal the flex cable from the surface of the flash capacitor. Use isopropyl alcohol to soften the glue if necessary.
Step 22

Remove eye piece assembly

  • Remove two 5.0 mm #00 screws.
  • Remove the eye piece.
  • The outer cover of the eye piece is only attached with double sided tape and may come away on its own. Make sure the entire eye piece unit is removed before proceeding.
Step 23

Remove lens release switch

  • Remove one #00 screw.
  • Reassembly Note: Ensure that the lower contact catches on the plastic nub and that the contact is open when the lens release button is not pressed.
Step 24

Flip the mirror up

  • Rotate the black gear downward until the mirror flips up into the taking position. It may take several turns.
  • Some failures will result in the mirror appearing to be in the upper position but the internal mechanism is still "down". The mechanism needs to be moved to release the mirror box.
Step 25

Detach flex circuit

  • Remove one 4.0 mm screw.
  • Gently lift the flex circuit away from the housing.
Step 26

Unscrew the mirror box

  • Remove two 6.5 mm #0 screws.
  • Remove one 8.0 mm #0 screw.
  • Remove one 4.0 mm #00 screw.
  • Remove one 4.5 mm #00 screw.
  • Remove two 2.5 mm #00 screws.
  • There may be a shim washer here. Remove if loose.
  • Remove one 4.0 mm #00 shoulder screw.
Step 27

Remove the mirror box

  • Push the mirror box up to free it from the bottom plate.
  • Lift the left side of the mirror box and rotate it up and out of the camera body.
  • Be gentle. Keep an eye out for any snagged flex cables or wires. The right side of the mirror box is still connected to the camera body and it cannot be completely removed.
  • Check for shim washers at the mount locations. Note location and remove if loose.
Step 28

Remove the mirror motor plate

  • Desolder the black wire.
  • Remove one 3.0 mm #00 screw securing the mount LED.
  • Remove five 3.5 mm #00 screws.
Step 29

Remove mirror motor

  • Remove two #00 screws
Step 30

Install new gear

  • Pre-heat the brass gear to slightly expand the size of the bore.
  • Carefully but firmly press the motor shaft into the still hot gear.
Step 31

Check drive gear aligment

  • The drive gears are easily knocked loose when working in this area. Ensure that the indicated holes are aligned before beginning reassembly.
Step 32

Prepare mirror motor plate for install

  • Install the mirror motor.
  • Slide the aperture actuator to the left.
  • Pinch the small lever downward and let it snap back into place.
  • The aperture actuator should be held in place on the left end of its travel if done correctly.
Step 33

Prepare mirror box assembly for install

  • Install mirror motor plate.
  • Turn the black gear downward until the mirror moves to the upper position.
  • Continue turning the black gear until this hole appears in the opening and the shutter charge lever moves to the right.
Step 34

Install mirror box

  • Make sure all wires and flex cables are in their proper place before beginning the install. Monitor carefully to avoid pinching things in the wrong place.
Step 35

Check functionality

  • Apply a low DC voltage (3-6 V) to the mirror motor to check the operation of the mirror box. Normal movement in the shutter blades, aperture actuator and mirror should be observable.