Step 1

Repair step

  • Before performing any repairs, perform a water test on the pump by raising and lowering the handle a full 40 strokes. A properly performing pump will yield greater than 10 liters.
  • Use a Tara tool to loosen the jam nuts on either side of the pump.
  • The bolts do not need to be loosened or removed, only the nuts need to be loosened.
Step 2

Repair step

  • Unscrew the lock bolts about half an inch.
  • The bolts do not need to be removed from the base.
Step 3

Repair step

  • Pull the plastic bushing and handle straight up out of the pump.
  • If the bushing doesn't come up, loosen the lock bolts further.
Step 4

Repair step

  • Lift up the handle and riser main until the joint between the two is at a comfortable height to work on.
Step 5

Repair step

  • Loosen the jam nut beneath the pump handle using the Tara tool.
Step 6

Repair step

  • Unscrew the pump handle from the top of the riser main.
  • Make sure someone is tightly holding the lower portion of the riser main to prevent losing it down the well.
Step 7

Repair step

  • Lift and remove the handle from the pump. Store the handle in a sanitary place to prevent contamination.
Step 8

Repair step

  • Screw the T-handle onto the top of the riser main.
Step 9

Repair step

  • Tighten the jam nut up against the base of the T-handle.
Step 10

Repair step

  • Use the T-handle to push the riser main back down into the well.
Step 11

Repair step

  • Once the riser main hits the bottom, turn the T-handle while pushing down.
  • This will hook the foot valve onto the traveling valve, allowing you to pull the two out of the well together.
  • You should feel some resistance if the foot valve is successfully attached.
Step 12

Repair step

  • Use the T-handle to pull the riser main straight up out of the well.
  • Take care to pull up slowly to ensure the foot valve does not get released from the hook at the end of the riser main.
Step 13

Repair step

  • Continue pulling the riser main up from the well.
  • Pull the riser main until the base of the T-handle is at a comfortable height to work on.
Step 14

Repair step

  • Loosen the jam nut from the base of the T-handle.
  • Unscrew the T-handle from the top of the riser main.
  • Remove the T-handle, making sure to hold the remaining end of the riser main to prevent dropping it down the well.
Step 15

Repair step

  • Continue to pull the riser main out of the well.
Step 16

Repair step

  • Keep pulling until the first joint is exposed.
  • Lift the joint up to a comfortable working height.
Step 17

Repair step

  • Use two wrenches to loosen the top section of riser main from the lower section.
  • Unscrew the top section of the riser main.
  • Make sure someone is holding the remaining section of the riser main.
Step 18

Repair step

  • Remove the top section of the riser main.
Step 19

Repair step

  • Lay the first section of riser main in a sanitary place to prevent contamination.
  • Repeat the previous procedure to remove the remaining sections of the riser main from the well.
  • Lay each new piece in the order it was removed to aid in reassembly.
Step 20

Repair step

  • The last section of riser main will have the traveling valve screwed on to the end, and the foot valve hooked onto the traveling valve.
  • Be careful not to allow the foot valve to release from the hook by pulling slowly on the riser main.
Step 21

Repair step

  • Lift and twist the foot valve to unhook it from the traveling valve.
Step 22

Repair step

  • Once the riser main and valves have been removed from the well, place a rag over the top to prevent accidentally dropping anything down the well.