FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Saeco Royal HD8920 Pump Replacement

The Royal HD89.. models are a later edition of...

iFixit Library Saeco Royal Moderate No estimate Guide 161653
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

The Royal HD89.. models are a later edition of the Royal, which differ significantly on the inside from the old SUP... series. If the pump is no longer working, you must replace it. This guide can also help with other Saeco models and with fully automatic coffee machines from Philips and Gaggia – the devices all come from the same manufacturer and have a very similar internal structure.

Step 1

Preparing

  • Unplug!
  • Remove all attachments like water tank, brewing unit etc.
  • The pictures show a Royal Cappucino One Touch HD8930, but the opening procedure is similar to all models.
Step 2

Top

  • The coffeebean supply is fixed with two screws. Unscrew them and lift it off.
  • There is a black rubber lid under the bean hopper that you can easily lift off, leaving a large opening.
  • The adjuster of the grinder has to be solved. Mark the position or just take a picture. This type is fixed with a screw, others are only sticked together.
Step 3

Rear side

  • There are two screws to be turned out.
Step 4

Front

  • The screws are situated on the underneath of the cover. This type is held by four screws.
Step 5

Lift cover off

  • Now the cover can be raised: first grip on left and right rear side and lift about 10 cm (4 in). Sometimes the cover jams a little bit.
  • Solve the hoses which lead to the water tank. Perhaps you have to pull out some contacts, (e.g. the yellow-green protection lead), don´t forget to put them on again later.
  • The cover can be drawn aslant towards the front, sliding it over the hot water pipe.
  • Most repairs can be done with the cover being laid up partially , it must not be completely removed.
Step 6

Repair step

  • The new pump is visible here: an ULKA EP5GW.
Step 7

Repair step

  • For this repair, you must remove the top cover completely.
  • Disconnect all connections:
  • Pull off all silicone hoses, if you haven't already.
  • Very carefully pull off the hot plate connector. Unscrew both eyelets on the green-yellow ground wires of the hot plate.
  • Carefully pull off the connector on the water level sensor and release the cable.
  • It is a little tricky to release the sensor for the bean hopper lid: release the side tabs and lift the sensor housing slightly upwards, then pull the sensor mounting out of the housing. Pull the sensor outwards and let it drop through the opening.
Step 8

Repair step

  • To reach the pump, the heater must be moved out of the way. This is not difficult; all connections can remain attached.
  • Remove the three Torx T10 screws at the top of the heater mounting plate.
  • Lift the heater out and set it aside. The connections remain attached, but be careful not to damage them.
Step 9

Repair step

  • The pump is secured to a support plate at the very bottom of the device. The plate must be removed, then you can remove the pump quite easily.
Step 10

Repair step

  • Remove the four Torx T10 screws on the left, at the rear, and inside the device:
  • The pump is still held in place by the power switch unit. Remove the two Torx T10 screws securing the power switch unit. One is right next to the pump on the inside, and one is on the back of the case.
  • Remove the two Torx T10 screws securing the pump mounting plate. One is at the bottom on the left side, and one is at the bottom on the back.
Step 11

Repair step

  • The power switch unit is now loose and you can slide it slightly to the side to clear the way for the pump support plate.
  • Disconnect the silicone hoses.
  • Lift the pump support plate out with all sockets. Work slowly and carefully, and make sure that no socket is damaged.
Step 12

Repair step

  • Disconnect the spade connectors.
  • Slide out the thermal fuse. If it is stuck, you will need to carefully release the adhesive.
  • Pry off the elbow connector.
Step 13

Repair step

  • Pry up the left black rubber holder so that the pump is free on the left side.
Step 14

Repair step

  • Unscrew the entire pump from the right fitting using a 13 mm open-end wrench. Watch out for the gasket; it is best to replace it with a new one.
Step 15

Repair step

  • Pry the pump out of the right rubber mount.