Disassembly of the Siemens Q5.0

Here, I'll show you how to take this vacuum...

iFixit Library Siemens Q5.0 Easy 6 minutes Guide 161689
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Here, I'll show you how to take this vacuum cleaner apart. This allows you to test the cord or rewind it, and repair or replace the PCB if necessary. Warning! For vacuum cleaners with a cord, a cable break often occurs directly at the power plug. Before disassembling the device, a cable break should first be ruled out. ******

Step 1

Checking for a cable break

  • If a vacuum cleaner is not working, always check the cable first.
  • If the cable is damaged and the wires are already visible, do not touch it under any circumstances.
  • Plug in the connector, turn on the device, and move the cable. If there is a cable break, the motor may start or turn off.
  • If there is a cable break, replace the entire cable up to the cable reel. If that is not possible, replacing the cable reel might be easier. Alternatively, shorten the cable and replace the connector. Attention! Do not use a screw-on Euro-plug. These have a load limit (A) that is too low.
  • Replace the connector with a rubberized connector with a strain relief and a sufficient load limit. A protective earth conductor is generally not required for vacuum cleaners.
Step 2

Unscrew the cover

  • Remove the 4 Torx screws.
  • Using a flat screwdriver, lever out the large switch at the side. Pay attention to the spring.
  • Remove two more Torx screws
  • Now the cover can be lifted off.
Step 3

Removing the circuit board

  • Unclip the potentiometer. Do not change the position. That way the rotary switch will fit again during assembly.
  • The circuit board can now be pulled out upwards. When mounting, make sure that the two contacts of the cable drum are inserted between the terminal contacts on the circuit board.
  • The cable drum sits loose in the housing and can be pulled out upwards.
Step 4

Cable reel

  • If the cable is not wound up cleanly, it can be helpful to unwind the cable completely. To do this, remove the drum. Then rewind the flat cable without twisting.
  • Cable reel If the cable is not wound up cleanly, it can be helpful to unwind the cable completely. To do this, remove the drum. Then rewind the flat cable cleanly without twisting. Before installing the reel, it can be pretensioned by turning it while it is still wound up, or the pretension can also be increased.
Step 5

Rotary switch

  • Rotary switch For the reassembly it may be necessary to remove the blue rotary switch beforehand. Put it back on the potentiometer only after the housing cover has been mounted.
  • The rotary switch can be unclipped from the inside.