Bush Pump Spout Replacement

Follow this guide to remove and replace or...

iFixit Library Bush Pump Moderate No estimate Guide 16171
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Follow this guide to remove and replace or repair the spout on a Bush pump.

Step 1

Repair step

  • Test pump performance by pumping 40 strokes.
  • An effective pump should return at least 10 liters.
Step 2

Repair step

  • Remove the two pins connecting the handle to the slider.
Step 3

Repair step

  • Pull the two lever arms away from the slider.
Step 4

Repair step

  • Lift the two pins attaching the pump frame to the head and handle up, off of the pump frame.
Step 5

Repair step

  • Throughout this step, make sure you support the handle and head with at least three hands.
  • Slide the bearing rod out of the head.
  • Inspect the bearing rod and head for any wear or tear.
Step 6

Repair step

  • Remove the head and handle, and place them on a clean surface to prevent contamination.
Step 7

Repair step

  • Firmly lift the riser main slider with two hands.
  • Use caution not to drop the riser main, as this can damage the pump cylinder.
Step 8

Repair step

  • Use a pipe wrench to fully loosen the above grade riser pipe.
Step 9

Repair step

  • Lift the slider and riser main pipe.
  • Place a pump rod clamp around the rod, and tighten it securely against the pump rod.
  • Carefully lower the riser main and slider to allow it to rest on the rod clamp.
Step 10

Repair step

  • Loosen and remove both the pump rod jam nut and pump rod nut on the top of the slider.
Step 11

Repair step

  • Remove the riser main slider, and inspect it for wear and tear.
  • Set the slider in a sanitary place to prevent contamination.
Step 12

Repair step

  • Remove the above grade riser pipe.
  • Firmly screw a T-handle onto the pump rod.
  • If you are replacing the above ground riser main, leave the T-handle attached until you are ready to install the replacement part.
Step 13

Repair step

  • Use a pipe wrench to loosen and remove the pump spout.
  • Inspect the spout for obstructions or potential contaminants.
  • Place the spout on a clean surface to prevent any contamination.